G
F
B
A
D
E
IVTP-1M-FL
657 mm
977 mm
397 mm
510 mm
410 mm
103 mm
290 mm
756 mm
1076 mm
450 mm
669 mm
465 mm
92 mm
320 mm
A
B
C
D
E
F
G
IVTP-2M-FL
IVTP-3M-FL
IVTP-4M-FL
IVTP-5M-FL IVTP-6M-FL
pH +/-
C
300 mm mini
1m = OK
300 mm mini
1m OK
300 mm mini
X
Y
IVTP-1M-FL / IVTP-2M-FL / IVTP-3M-FL / IVTP-4M-FL :
X : 1200 mm Y : 650 mm
IVTP-5M-FL / IVTP-6M-FL:
X : 1300 mm Y : 700 mm
3m
5
4
INSTALLATION (SITE, TYPE OF SUPPORT, NECESSARY SPACE)
DIMENSIONS:
HYDRAULIC CONNECTIONS:
–Install the HP outdoors at more than 2 metres from the pool, as per applicable laws (NF C 15 100).
–Place the HP on the provided vibration absorbers on a surface that is stable, solid (able to bear the weight of the device) and level (prepare a concrete base
if necessary).
–Maintain 1 m (30 cm minimum) of open space in front of the vertical air intake grids (behind and on the side of the HP) and 3 m at the outlet of the fan (in
front) of open space without any obstacles.
–Prepare sufficient space around the HP for maintenance operations.
–Prepare a water evacuation system close to the HP to protect the installation zone.
–Keep the HP out of the reach of children, insofar as possible.
The HP should never be installed:
–in an area covered by sprinkling systems, or subject to spray or running water or mud (close to a road, take into account the effects of wind),
–under a tree,
–close to a source of heat or of flammable gas,
–in an area where it would be exposed to oil, flammable gases, corrosive products, and compounds containing sulphur,
–close to equipment operating at high frequencies,
–in a place where snow is likely to accumulate,
–in a place where it could be flooded by the condensates produced by the device as it operates,
–on a surface that could transfer the vibrations to the house.
Advice: dampen the possible noise nuisance caused by your HP.
–Do not install it close to or underneath a window.
–Do not direct the outlet of the fan towards your neighbours’ property.
–Do not direct the fan outlet (cold air) towards the swimming pool.
–Install it in an open area (sound waves bounce off surfaces).
–Install a sound barrier around the HP, making sure to maintain the required distances.
–Install 50 cm of PVC piping at the water inlet and outlet of the HP.
To improve its performance, it is recommended to insulate the piping between the HP and the swimming pool, especially if the distance is significant.
–Water quality necessary for this device: NF-EN-16713-3
–The HP is compatible with all types of water treatment. The HP must imperatively be connected by a PVC pipe of Ø 50mm to the swimming pool’s hydraulic
circuit, after the filter and before the treatment system, regardless of its type (Cl, pH, Br metering pumps and/or electrolyser).
–Follow the hydraulic connection order (blue = water in, red = water out)
–A bypass must be installed to facilitate work on the HP.
–Before connecting the PVC pipes to the HP, make sure the circuit is clean of any work residue (stone, soil, etc.).
Connection of the condensate evacuation pack:
During operations, the HP is subject to a condensation phenomenon. This translates into a water flow, which can be more or less important depending on the
degree of humidity. To channel this flow, which can represent several litres of water per day, we recommend you install the provided condensate evacuation
pack and connect it to a suitable water evacuation circuit.
Space to maintain around the HP:
Provided connections
(ø 50mm)
HP
Condensate evacuation
Bypass
Bypass valve
(adjustment)
Open valve
Half-open valve
Closed valve
FROM THE SWIMMING POOL
TOWARDS THE SWIMMING POOL
Water treatment (disinfection, pH correction)
located after the HP
Provided skid
Minimum dimensions of the concrete slab
The HP must be installed and maintained on a fixed and solid basis, with the skids placed under the
feet.
–For concrete, use adapted ø8 mm lag screws fitted with washers to prevent any loosening.
–For wood, use adapted ø8 mm hexagon head screws fitted with locking washers to prevent any
loosening.
–Cover the front of the feet with the provided hoods, push down to the clipping system.