Pentair INTELLIpH Installation And User Manual Download Page 10

INTELLIPH

®

 ACID DISPENSER Installation and User’s Guide

6

Troubleshooting

Refer to the following tips to help to resolve problems that might occur while operating 
the IntellipH

®

 Acid Dispenser System. 

 

SYMPTOM 

POSSIBLE CAUSE 

SOLUTION 

 

 

 

pH too high in pool 

 

Intelli-pH not “tuned” to pool 

needs. 

 

Press MORE button to increase 

Dispense Amount. 

pH too low in pool 

 

Intelli-pH not “tuned” to pool 

needs. 

 

Press LESS button to decrease 

Dispense Amount. 

Acid pump does not run 

 

Hourly acid dose size is too small 

to dispense every hour. 

 

Press MENU, then MANUALLY 

DISPENSE ACID. This will activate 

pump. 

 

Increase Dispense Amount 

setting. 

 

Pump not working. Replace pump.

 

System Status Light is red 

 

Attempted to dispense acid, but 

no flow was seen in cell. 

 

IntelliChlor cell was not ready 

(Intellichlor salinity lights scrolling, 

indicating cell is on status check). 

 

Cell communication link is down. 

 

 

Cold Water is < 52°F (12.2°C) 

or below. 

 

 

Check and confirm enough water 

flow through IntelliChlor® SCG.

 

 

Wait until the IntelliChlor® SCG

  

finishes the 2 min. salinity check

cycle.

 

 

 

Check terminal block from 

IntelliTouch® or EasyTouch®

Control System.

 

 

Unit will not dispense. 

To Refill the IntellipH Acid Canister

Always follow basic safety rules when handling acid. Read and follow the manufactures 
instructions on the acid container. 

• 

Always wear safety glasses

• 

Wear rubber gloves

• 

Refill canister in an open area; not in an enclosed space

 

To refill the acid canister:

• 

Refill the canister by carefully and slowly tilting the tip the canister into the 
acid tank then push down to puncture the foil.  To speed up acid dispersal 
into the tank, use a sharp object to puncture the bottom of the gallon of 
acid.  

How to refill the IntellipH acid canister

 

Summary of Contents for INTELLIpH

Page 1: ...TELLIPH ACID DISPENSER Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE INTELLIpH ACID DISPENSER SYSTE...

Page 2: ...d Acid Manually 3 Dispense Amount 4 Superchlor Mode 5 Set Cell Output 5 Cell Status 5 History Data 5 Troubleshooting 6 How to refill the IntellipH canister 6 IntellipH Installation 7 Setting up the sy...

Page 3: ...quipment IMPORTANT WARNINGS AND SAFETY INSTRUCTIONS Be sure that the pool or spa meets the requirements of the current National Electrical Code N E C Article 680 22 and all local codes and ordinances...

Page 4: ...should be thoroughly cleaned before re use EYE CONTACT Flush eyes immediately with water for at least 20 minutes Seek immediate medical attention PERSONAL PROTECTION VENTILATION Use container outside...

Page 5: ...the IntellipH controller control panel display will show a 60 minute countdown timer When the timer equals zero the pump on the canister is activated and acid is pumped into the pool s main waterline...

Page 6: ...ntroller is powered off Less More buttons Scroll through the main menu items and adjust or change settings Use these buttons after pressing the Menu button to scroll through the main menu items Enter...

Page 7: ...ller Dispense Amount 0 100 IntelliChlor SCG cell model Menu Button Press the MENU button to display the system choices Use the MORE or LESS button to scroll through each choice Press the ENTER button...

Page 8: ...e this percentage or press the LESS button to lower this percentage Press the MENU key to exit this mode The new settings will be saved in memory If the water pH is low press the LESS button to decrea...

Page 9: ...SCG In Superchlor mode the pool filter pump is not controlled by the IntellipH Controller Set Cell Output This setting controls IntelliChlor SCG sanitizer output and has a range of 0 100 The default f...

Page 10: ...as not ready Intellichlor salinity lights scrolling indicating cell is on status check Cell communication link is down Cold Water is 52 F 12 2 C or below Check and confirm enough water flow through In...

Page 11: ...ay will be blank which indicates no chlorine is being produced The IntellipH dispenser will display SYSTEM OFF WILL NOT DISPENSE No acid will be dispensed during this time If the automation panel is i...

Page 12: ...to the bottom of the IntellipH Controller 4 Plug the IntellipH Controller cord into the IntelliChlor SCG Power Center IntelliTouch or EasyTouch Control System load center where the IntelliChlor SCG ce...

Page 13: ...drill through the pipe 3 Clean all burrs from inside and outside of the hole If necessary use fine sandpaper to remove the burrs Install the Saddle Clamp 1 Thread the injector fitting into the top of...

Page 14: ...f cracked P N 522386 8 Ensure rollers spin freely 9 Note if the rollers are seized or visibly worn replace roller assembly 10 Re install roller assembly Figure 1 Figure 2 Pull lock lever tab from left...

Page 15: ...ing cover with track and slide over tube to seat the cover in place See Figure 5 3 To lock cover in place push lock lever down on the cover while turning the vertical tab180 from right to left See Fig...

Page 16: ...tubing is cut square and the ends are clean Do not overtighten the nuts and ensure that the pump head tube is not twisted 5 Cut enough tubing to connect the Outlet of the pump to the Injection Check...

Page 17: ...ng through the supply injector fitting cap Connect tubing onto the acid injection fitting and tighten cap securely before turning the pump on Tube Inlet nut Do not overtighten Tube Outlet nut Do not o...

Page 18: ...ls 20 ft 522446 1 4 Black Tubing for Chemical Injection with Labels 100 ft 1 522386 Repair Kit for Tank Mounted Pump 2 522480 Pump Tubes for Tank Mounted Pump 2 pack 3 522895 Injection Kit Includes In...

Page 19: ...INTELLIPH ACID DISPENSER Installation and User s Guide 14 3 6 4 5 1 2 3 7 8 10 9 1 2 IntellipH Controller and Chemical Canister Replacement Parts...

Page 20: ...n the United States and or other countries Unless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the...

Reviews: