![Pentair INTELLICHLOR Installation Manual Download Page 3](http://html.mh-extra.com/html/pentair/intellichlor/intellichlor_installation-manual_1524774003.webp)
INTELLICHLOR
Flow-Temperature Switch Replacement Kit Installation Guide
1. Remove the flow switch cover from
the cell.
2. Loosen the flow-temperature switch
cable that is wrapped around the
switch nut. Note the direction of the
arrows on top of the switch nut.
3. Cut the cable close to the switch
to allow enough wire for the
new switch cable to be
connected to.
4. Using a flat 1-3/16”
(30 mm) wrench
carefully unscrew the
flow-temperature
switch assembly until
the switch can be
remove from the cell.
Be careful not to
damage the cell
plastic coupling with
the edge of the wrench.
1
IntelliChlor
®
Salt Chlorine Generator
Flow-Temperature Switch Replacement Kit Contents
Replacement kit contents:
•
Flow-Temperature switch assembly
•
Two pair-at-a-time splicer
Step 1: Switch OFF power to the pool pump and the
IntelliChlor Salt Chlorine Generator cell before
starting.
Step 2: Remove the flow-temperature switch from the
IntelliChlor Salt Chlorine Generator cell.
Cut wire
Unscrew nut
counterclockwise to
remove flow-
temperature switch
assembly
To remove the flow-temperature switch from the IntelliChlor Salt
chlorine Generator cell: