Pentair INTELLICENTER Installation Manual Download Page 15

 

IntelliCenter Control System Indoor Control Panel Installation Guide

 

 

                                 

IntelliCenter Control System Indoor Control Panel Installation Guide 

                                                                                                                                                                                            

9

 

IntelliCenter

 Automation System For Pool and Spa Menu

    

Home Screen: 

 

Pool Screen 

 

Spa Screen 

 

Features (Individual/Groups) 

 

Lights (Individual/Groups) 

 

Schedule (Weekly, One Time Only Schedule) 

 Usage 

 

Chemistry (IntelliChem

®

 Controller/IntelliChlor

®

 SCG) 

 Status
 

Settings: 

    Service Mode 

    Vacation Mode 

   Support 

    General: Location, Date & Time, Units (Fahrenheit/Celsius), Features  

    and Lights List Order, General List Order, Backlight (Deep Sleep): Wireless    

 

 

 

    Control Panel only, Temperature Sensor Calibration, Day / Night Themes, Manual Operation Priority,   

    Manual Heat, Chemistry Readings Badge, Badge Colors. 

    Alerts and Notifications: Choose which system status, alerts and warnings    

 

 

 

    badges to display on the Home screen Status icon. 

    Security (Passcode Protect) 

    Pentair User Portal (intellicenter.com) 

    Groups: Configure groups of AUX circuits, Light circuits and Feature circuits. 

    System Reboot: Reboot the panel

 

Advanced System Configuration 

  

Installation Setup:

 

      Body Configuration,Circuits, Pumps, Heaters, Valves,  

 

 

 

 

 

 

    Chemistry, Pool/Spa Cover. 

 

    Remotes Setup: iS4, QuickTouch II, iS10, SpaCommand remotes 

    Network and WiFi Setup: Configure Ethernet, Connect to a Wireless 

    Network, Adjust Wireless Transmit Power, Internet Connection Test, 

    Reboot WiFi Device. 

    IntelliCenter Wireless Remote Setup: Configure the Address and Panel # 

    for wireless remote. 

    Delays: Valve Delay, Heater Cool Down, Freeze Cycle Time (min), Spa Freeze    

 

 

 

    Override (min), Override Delays. 

    System: System Information, Detected Hardware, System Diagnostic  

 

 

 

 

    Information, Firmware Update (Update from Panel, Update from USB, 

    Update from Ethernet), Factory Diagnostics.

          

Import/Export: Import System Configuration,  Export System Configuration.

            

Restore Factory Defaults:

 Restore system to factory configuration. 

            Setup Wizard: Step-by-step system configuration.

Summary of Contents for INTELLICENTER

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INTELLICENTER CONTROL SYSTEM INDOOR CONTROL PANEL INSTALLATION GUIDE ...

Page 2: ... Indoor Control Panel Communication Cable to the Personality Circuit Board 5 Configuring the Indoor Control Panel 6 Using the USB Port to Import Export a System Configuration 7 Indoor Control Panel Firmware Update 8 IntelliCenter Control System Menu 9 P N 523229 Rev D 2 2020 CUSTOMER SERVICE TECHNICAL SUPPORT Customer Service 8 AM to 8 PM Phone 800 831 7133 Fax 800 284 4151 Visit www pentair com T...

Page 3: ...plications only Most states and local codes regulate the construction installation and operation of public pools and spas and the construction of residential pools and spas It is important to comply with these codes many of which directly regulate the installation and use of this product Consult your local building and health codes for more informa tion This guide provides installation and operati...

Page 4: ...or use in other than single family dwellings a clearly labeled emergency switch shall be provided as part of the installation The switch shall be readily accessible to the occupants and shall be installed at least five 5 feet 1 52 m away adjacent to and within sight of the unit Except for listed spa side remote controls install a minimum of five 5 feet 1 52 m from the inside wall of the pool and s...

Page 5: ...ing this equipment no smaller than 12 AWG or 3 3 mm The bonding lug s provided on this unit are intended to connect a minimum of one No 8 AWG for US installation and two No 6 AWG for Canadian installations solid copper conductor between this unit and any metal equipment metal enclosures or electrical equipment metal water pipe or conduit within 5 feet 1 5 m of the unit 5 The electrical supply for ...

Page 6: ...vi IntelliCenter Control System Indoor Control Panel Installation Guide Blank Page ...

Page 7: ...an actuator to be assigned without using an existing auxiliary circuit 16 Groups Assign groups of lighting heaters pumps circuits that can be controlled by a single button Supports up to 16 IntelliFlo VF and VS Pumps Supports up to four SpaCommand and iS10 Spa Side Remotes and 2 iS4 and QuickTouch II Wireless Spa Side Remotes Supports IntelliBrite LED Color lights Valves Intake Return plus A and B...

Page 8: ...lectrical connections 4 FROM THE INDOOR CONTROL PANEL LOCATION Route the four conductor RS 485 connection cable from the Indoor Control Panel location into the Load Center lower plastic grommet up through the low voltage raceway to the system circuit board 5 Connect the communication cable conductors to the COM PORT J15 or J16 connector See page 5 7 After Connecting the RS 485 cable to the Indoor ...

Page 9: ... Remove the Indoor Control Panel front cover from the back plate Unsnap the bottom edge of the front of the Indoor Control Panel cover from the back plate See illustration on next page 2 Use the cutout backplate template shown below or the actual backplate against the mounting surface so that it is oriented in an upright position Use a pencil to mark the two or four screw locations on the mounting...

Page 10: ...the screw terminal connector onto the transceiver circuit board The preferred wire color scheme is Red Yellow Green and Black 5 Mount the Indoor Control Panel cover over backplate and snap in place to secure 6 Run a UL approved four conductor cable 22 AWG from the Indoor Control Panel to the Load Center NOTE Use 18 AWG conductor cable for distances longer that 200 ft Connecting the Communication C...

Page 11: ...ion cable terminal plug onto the COM PORT J15 or J16 connector IntelliCenter Automation System Circuit Board Connect Indoor Control Panel communication cable to COM port J15 J16 COMMUNICATION PORTS A B 14 VDC 2 0A Max Combined IntelliCenter Control System COM PORT Strip 1 4 insulation from the green and yellow wire conductors Connect the Green wire to pin 2 on Connector J15 or J16 Connect the Yell...

Page 12: ...anel Home screen displayed is applied from the IntelliCenter System Load Center Outdoor Control Panel Verify that the IntelliCenter System Load Center is powered on If not switch on the main circuit breakers to apply power to the Load Center 2 From the Home screen on the Indoor Control Panel tap Settings Advanced System Configuration Installation Setup Body Configuration 3 Tap Indoor Control Panel...

Page 13: ... and select the configuration file cfg to import Import for USB Insert a USB device into the USB Port on the front of the IntelliCenter Automation System Indoor Control Panel Tap Import from USB and navigate to the system configuration file CFG Follow the on screen instructions to import the system configuration files Import to Local Tap Import from Local and follow the on screen instruction Impor...

Page 14: ...pdate from Panel Update from USB Check for Update Check for Update Tap this button to check for the latest firmware version Follow the screen prompts Firmware Update Tap this button to display the Firmware Update screen This screen displays the current firmware version Update from USB Insert the USB device into the Outdoor Control Panel Indoor Control Panel or Wireless Remote Tap the Update From U...

Page 15: ...r Portal intellicenter com Groups Configure groups of AUX circuits Light circuits and Feature circuits System Reboot Reboot the panel Advanced System Configuration Installation Setup Body Configuration Circuits Pumps Heaters Valves Chemistry Pool Spa Cover Remotes Setup iS4 QuickTouch II iS10 SpaCommand remotes Network and WiFi Setup Configure Ethernet Connect to a Wireless Network Adjust Wireless...

Page 16: ...Pentair trademarks and logos are property of Pentair Inc or its global affiliates in the U S A and or other countries Third party registered and unregistered trademarks and logos are the property of their respective owners 2020 Pentair All rights reserved This document is subject to change without notice 523229 P N 523229 Rev D 2 2020 ...