background image

5

Warranty Is

Void, If…

1. Power cord has been cut or 

the grounding prong has been 

removed.

2. Unit has been used in an 

outdoor application.

3.  Batteries not meeting the above 

specifications have been used.

4. Unit has been submerged in 

water.

5.  Unit has been tampered with 

in any manner not described in 

the above instructions.

6.  Unit has been disassembled by 

customer.

100

10

20

30

40

50

60

70

80

90

1

2

3

4

5

6

7

8

9

10

11

A+ Battery Backup performance with a Hydromatic B-A1 Pump

Run Time (hours)

Duty Cycle (percent)

Test results are based on the 

following criteria:

Pump Current Draw: 5.8 Amps

Specific gravity of

battery fluid at the

start of each test:  

1300

Start: 

  13.45 

Volts

Finish:  

 

10.2 Volts

7. Unit has been applied to 

products exceeding the 

maximum capacity of the Unit.

8.  Unit has been applied to the 

wrong voltage.

9. The A+ Battery Backup 

System is used with any other 

pump than the Hydromatic  

B-A1 pump.

Summary of Contents for HYDROMATIC A+

Page 1: ... 957 8677 Unit Installation and Service Manual A Battery Backup Power Supply For use with Hydromatic model B A1 BV A1 2013 Pentair Ltd All Rights Reserved W 03 422 Rev 03 04 13 NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system ...

Page 2: ...attery Backup System is to be used only with the Hydromatic pump supplied with the Unit Using anything other than the pump supplied with the system will cause damage to the Unit and void the warranty Tools Needed A pipe wrench pliers adjustable wrench and screwdriver will be needed Battery Requirements Your Unit operates on 12V DC battery power when in the power fail mode a UL recognized deep cycl...

Page 3: ...rging light OFF C Fully charged light OFF D If fully charged light ON 4 AFTER EACH 5 MINUTES OF OPERATION the Unit halts inverter operation for 5 seconds to test for receptacle power pump stops A Power loss inverter on light OFF may slowly dim B Battery charging light OFF C Fully charged light OFF D If receptacle power is found to be present see 2 above E If receptacle power is found to be off see...

Page 4: ...dried e CAUTION Lead acid batteries can present a risk of fire because they generate hydrogen gas The following procedures should be followed f DO NOT SMOKE when near batteries g DO NOT cause flame or spark in battery area h Discharge static electricity from body before touching batteries by first touching a grounded metal surface 11 See battery manufacturer s installation manual for additional ba...

Page 5: ... by customer 100 10 20 30 40 50 60 70 80 90 1 2 3 4 5 6 7 8 9 10 11 A Battery Backup performance with a Hydromatic B A1 Pump Run Time hours Duty Cycle percent Test results are based on the following criteria Pump Current Draw 5 8 Amps Specific gravity of battery fluid at the start of each test 1300 Start 13 45 Volts Finish 10 2 Volts 7 Unit has been applied to products exceeding the maximum capaci...

Page 6: ...6 This page intentionally left blank ...

Page 7: ...7 This page intentionally left blank ...

Page 8: ... be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Sewage Pumps are warranted for a period of 12 months from date of purchase or 18 months from date of manufacture whichever comes first HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQ...

Reviews: