background image

4

HI FLOW™ Six-Way 1-1/2 Inch Top Mount Valve Installation and User’s Guide

Valve Care

The valve is a very important part of your pool equipment 
and system. Proper care and maintenance will add many 
years of service and enjoyment to the pool. Follow these 
suggestions for long trouble free operation:
1.  To clean the exterior of the valve of dust and dirt, 

wash with a mild detergent and water, then hose off. 
Do NOT use solvents.

2.  The valve clamp used on your valve has been 

manufactured with high quality corrosion resistant 
materials. The manufacturing process could allow 
sharp edges to be present on the parts. When working 
in and around the clamp use caution to prevent 
potential injury to fingers or hands from contact with 
sharp edges.

3.  Your valve is a pressure vessel and should never be 

serviced while under pressure. Always relieve tank 
pressure and open air bleeder before attempting to 
service your valve.

4.  Open the manual air bleeder and stand clear of the 

filter/valve before restarting your pump.

Winterizing

1.  Shut off pump and open the valve air bleeder.
2.  Drain and winterize the pump and filter per 

manufacturer’s instructions

3.  Press down on valve handle and rotate so valve 

pointer is on circular rib on valve top at area on valve 
marked WINTERIZE.

Note:

 The valve should be left in this position during 

the shutdown season so the valve diverter has no 
pressure on the rubber seal.

Always visually inspect valve 
components during normal servicing 

to insure structural safety. Replace any item which is 
corroded, bent or otherwise visually defective. Defective 
valve components can allow the valve or attachments to 
separate from the filter and could cause severe bodily injury 
and/or property damage.

MAINTENANCE

Replacing the Valve Top and Diverter 
Assembly

1.  Shut off pump and open air bleeder to relieve all 

internal pressure.

2.  Set valve handle to winterize position.
3.  Remove 6 cover screws (item 10).
4.  Lift off valve top and diverter assembly.

Note: 

Valve diverter assembly has the sealing gasket 

attached to the diverter. When handling the diverter 
use caution to prevent the sealing surface from being 
damaged during handling. 

5.  Clean valve body sealing surface with soft clean 

lint free cloth. Inspect surface for damage such as 
scratches or nicks. If surface is damaged the valve 
body must be replaced.

6.  Carefully lubricate the new valve top replacement 

o-ring (item 6) with a silicone based lubricant and 
place appropriately on valve top.

7.  Place the new valve top handle in the winterize 

position. Install new valve top and diverter assembly 
making sure small recess on lid and small bump on 
valve body are aligned. Start all 6 screws with fingers 
to insure that the screw is started in the formed 
thread of the valve body. Screws should be tightened 
progressively by tightening diametrically opposite 
screws and following a crisscross pattern. Tighten 
all 6 valve top attachment screws firmly. DO NOT 
OVERTIGHTEN.

Note:

 Valve top is attached with self-tapping screws. 

The screws must be aligned properly to prevent cross 
threading of the screws in the valve body.

HIGH PRESSURE: An improperly 
installed valve may separate from the 

filter and cause sever injury and/or property damage.

Summary of Contents for HI FLOW SIX-WAY 1-1/2 INCH TOP MOUNT VALVE

Page 1: ...PORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents Operation Valve Positions Installation Maintenance Replacing the Valve Top and Diverter Assembly...

Page 2: ...ent and possibly injury always turn the pump off before changing valve positions INSTALLATION The filter valve will be installed on to the filter in one of two ways depending upon the filter and valve...

Page 3: ...lter piping assembly in the center of the large filter opening can cause the valve to not thread properly into the filter tank Valve Flange Valve Clamp Half Tank Flange Figure 1 Use of lubricants or p...

Page 4: ...any item which is corroded bent or otherwise visually defective Defective valve components can allow the valve or attachments to separate from the filter and could cause severe bodily injury and or p...

Page 5: ...problem Sand blowing through air vent slots or between filter center pipe in valve Refer to filter troubleshooting in the filter manual Sand size too small or flow rate through filter too high Leakag...

Page 6: ...lass w Vacuum Protector 17 271107 Gasket Sightglass 5 8 I D x 1 O D 18 154493 O Ring 0 157 x 5 75 I D 155037 Carton 272517 Manual 19 272555 Washer 9 16 SS5 20 272554 Nut 10 24 Serrated Flange SS5 21 3...

Page 7: ...7 HI FLOW Six Way 1 1 2 Inch Top Mount Valve Installation and User s Guide NOTES...

Page 8: ...ted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and S...

Reviews: