Installer manual Fleck 5800 XTR - Programming
Ref. MKT-IM-006 / E - 12.11.2019
83 / 126
6.3.12
Chlorine generation screen
From the secondary master settings screen press the
cl generation/low salt
button to display the
chlorine generation screen.
Info
Cl generation/low salt will not be available for filter metered, immediate or delayed
regeneration type.
Mandatory
On the valves of series 5800, cl generation/low salt must be set OFF because the
chlorine cell kit managed by the XTR is not available for those valves.
Chlorine Gen./Low Salt
cl generation/
low salt
regen. interval
1
on
cl generation/low salt
: Contains settings for the chlorine generation. Select between OFF, low
salt detect. and ON.
regen. interval
: Contains the setting for the chlorine generation interval. Set up from 1 to 255 to
define the interval of regeneration between each chlorination activation, e.g. 1 so that it is enabled
at every regeneration or 10 so that it is activated every 10 regenerations for instance.
Press
to save and to return to the master settings screen or press
to return to the master
settings screen without saving.
6.3.13
Non-factory setting
After all parameters in master setting have been set, press
on the master settings screen to
display the non-factory settings screen.
Non-factory settings
current settings will
be saved as
the non-factory settings?