Installer Manual Fleck 4600 - MECH - Programming
48 / 88
Ref. MKT-IM-027 / B - 01.06.2018
6.3. Time
clock
6.3.1. Calculating the number of days between two regenerations
Set the number of days between two regenerations using the following formulas:
Water capacity [m
3
] = (Exchange capacity [m
3
°tH] - Reserve capacity [m
3
]) / Water hardness [°tH]
Number of days between regenerations = Water capacity [m
3
] / Daily water consumption [m
3
]
1. 24 hour wheel
2. Program
wheel
→ Defines the number of days between two regenerations.
3. Time of day
→ Shows the current time.
4. Service
position
→ Service;
→ Regeneration;
→ Backwash;
→ Brine draw/slow rinse;
→ Brine refill.
5. Red
lamp
→ Lights when the valve regenerate.
6. Green
lamp
→ Lights when in service.