Page 6
3200 Timer Setting Procedure
How To Set Days On Which Water Conditioner Is To
Regenerate (Figure 2):
Rotate the skipper wheel until the number “1” is at the
red pointer. Set the days that regeneration is to occur
by sliding tabs on the skipper wheel outward to expose
trip fingers. Each tab is one day. Finger at red pointer is
tonight. Moving clockwise from the red pointer, extend
or retract fingers to obtain the desired regeneration
schedule.
How To Set The Time Of Day:
1. Press and hold the red button in to disengage the
drive
gear.
2. Turn the large gear until the actual time of day is at
the time of day pointer.
3. Release the red button to again engage the drive
gear.
How To Manually Regenerate Your Water
Conditioner At Any Time:
1. Turn the manual regeneration knob clockwise.
2. This slight movement of the manual regeneration
knob engages the program wheel and starts the
regeneration
program.
3. The black center knob will make one revolution in
the following approximately three hours and stop in
the position shown in the drawing.
4. Even though it takes three hours for this center knob
to complete one revolution, the regeneration cycle of
your unit might be set only one half of this time.
5. In any event, conditioned water may be drawn after
rinse water stops flowing from the water
conditioner drain line.
How to Adjust Regeneration Time:
1. Disconnect the power source.
2. Locate the three screws behind the manual
regeneration knob by pushing the red button in and
rotating the 24 hour dial until each screw appears in
the cut out portion of the manual regeneration knob.
3. Loosen each screw slightly to release the pressure
on the time plate from the 24 hour gear.
4. Locate the regeneration time pointer on the inside
of the 24 hour dial in the cut out.
5. Turn the time plate so the desired regeneration time
aligns next to the raised arrow.
6. Push the red button in and rotate the 24 hour dial.
Tighten each of the three screws.
7. Push the red button and locate the pointer one more
time to ensure the desired regeneration time
is
correct.
8. Reset the time of day and restore power to the unit.
Figure 2
61502_3200REVA
Summary of Contents for FLECK 2750 Downflow
Page 9: ...Page 9 Notes...
Page 19: ...Page 19 Notes...
Page 31: ...Page 31 Notes...
Page 34: ...Page 34 Water Conditioner Flow Diagrams...
Page 35: ...Page 35 Water Conditioner Flow Diagrams...
Page 36: ...Page 36 Flow Data Injector Draw Rates...
Page 39: ...Page 39 System 4 Immediate Delayed Valve Wiring 19201_REVB...
Page 40: ...Page 40 System 4 Remote Signal Start Valve Wiring 13768_REVG...
Page 41: ...Page 41 System 5 Duplex Valve Wiring 40502 01_REVB 40502 02_REVB...
Page 42: ...Page 42 System 6 Duplex Valve Wiring 13632 01_REVK 13632 02_REVL...
Page 43: ...Page 43 System 7 Duplex 24V 120V 3 Way Valve Wiring 19138 01_REVD 19138 02_REVD...
Page 44: ...Page 44 System 7 Duplex 230V 3 Way Valve Wiring 17727 01_REVD 17727 02_REVD...
Page 46: ...P N 42327 Rev B 9 30 08...