background image

COMPONENTS

A) Pentair® Fleck 125 In-And-Out Valve
B) Bypass
C) Connector

B

A

B

1

3

4

4

3

2

1

2

TITLE

SIZE

SCALE

SHEET 1 OF 1

DWG NO.

REV

Pentair Residential

Filtration, LLC

CHECKED

APPROVED

APPROVALS

DATE

THIRD ANGLE

PROJECTION

DRAWN

B

1:2

REVISIONS

DATE

APP'D

DESCRIPTION

REV.

PCO

ZONE

A

DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]

INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009

UNLESS OTHERWISE SPECIFIED:

ALL FINISHED MACHINED SURFACES  125       OR BETTER.

TOLERANCES:

    

  ANGLES :       1

  1 PLACE  .X:    .015  [0.38]

  2 PLACE  .XX:    .01  [0.3]

  3 PLACE  .XXX:   .005  [0.13]

BR42887

THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR

RESIDENTIAL FILTRATION, LLC.  REPRODUCTION, USE 

DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR

DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS 

PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR 

RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS 

DOCUMENT AND ANY COPIES SHALL BE RETURNED TO

PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.

  COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS

B

A

B

1

3

4

4

3

2

1

2

TITLE

SIZE

SCALE

SHEET 1 OF 1

DWG NO.

REV

Pentair Residential

Filtration, LLC

CHECKED

APPROVED

APPROVALS

DATE

THIRD ANGLE

PROJECTION

DRAWN

B

1:2

REVISIONS

DATE

APP'D

DESCRIPTION

REV.

PCO

ZONE

A

DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]

INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009

UNLESS OTHERWISE SPECIFIED:

ALL FINISHED MACHINED SURFACES  125       OR BETTER.

TOLERANCES:

    

  ANGLES :       1

  1 PLACE  .X:    .015  [0.38]

  2 PLACE  .XX:    .01  [0.3]

  3 PLACE  .XXX:   .005  [0.13]

BR42887

THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR

RESIDENTIAL FILTRATION, LLC.  REPRODUCTION, USE 

DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR

DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS 

PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR 

RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS 

DOCUMENT AND ANY COPIES SHALL BE RETURNED TO

PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.

  COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS

B

A

B

1

3

4

4

3

2

1

2

TITLE

SIZE

SCALE

SHEET 1 OF 1

DWG NO.

REV

Pentair Residential

Filtration, LLC

CHECKED

APPROVED

APPROVALS

DATE

THIRD ANGLE

PROJECTION

DRAWN

B

1:2

REVISIONS

DATE

APP'D

DESCRIPTION

REV.

PCO

ZONE

A

DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]

INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009

UNLESS OTHERWISE SPECIFIED:

ALL FINISHED MACHINED SURFACES  125       OR BETTER.

TOLERANCES:

    

  ANGLES :       1

  1 PLACE  .X:    .015  [0.38]

  2 PLACE  .XX:    .01  [0.3]

  3 PLACE  .XXX:   .005  [0.13]

BR42887

THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR

RESIDENTIAL FILTRATION, LLC.  REPRODUCTION, USE 

DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR

DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS 

PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR 

RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS 

DOCUMENT AND ANY COPIES SHALL BE RETURNED TO

PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.

  COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS

A

B

C

PRODUCT SPECIFICATIONS AND OPERATION

Specification Description

Minimum Pressure

20 PSI

Maximum Pressure

125 PSI

Minimum Water Temperature

34°F (1°C)

Maximum Water Temperature

110°F (43°C)

Minimum Ambient Temperature

34°F (1°C)

Maximum Ambient Temperature

125°F

 (52°C)

Flow Rate

62134-01

62134-02

Downflow

Upflow

Downflow

Upflow

Continuous 

(15 psid drop)

54.9 GPM

[12.5 m

3

/hr]

47.4 GPM

[10.8 m

3

/hr]

62.3 GPM

[14.2 m

3

/hr]

62.6 GPM

[14.2 m

3

/hr]

Peak 

(25 psid drop)

70.9 GPM

[16.1 m

3

/hr]

61.2 GPM

[13.9 m

3

/hr]

80.4 GPM

[18.3 m

3

/hr]

80.7 GPM

[18.3 m

3

/hr]

Cv

 

(Flow at 1 psi drop)

14.2

12.2

16.1

16.2

FLECK® 125 IN-AND-OUT VALVE

Installation Instructions

B

A

B

1

3

4

4

3

2

1

2

TITLE

SIZE

SCALE

SHEET 1 OF 1

DWG NO.

REV

Pentair Residential

Filtration, LLC

CHECKED

APPROVED

APPROVALS

DATE

THIRD ANGLE

PROJECTION

DRAWN

B

1:24

REVISIONS

DATE

APP'D

DESCRIPTION

REV.

PCO

ZONE

A

DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]

INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009

UNLESS OTHERWISE SPECIFIED:

ALL FINISHED MACHINED SURFACES  125       OR BETTER.

TOLERANCES:

    

  ANGLES :     

 1

  1 PLACE  .X:  

 .015  [0.38]

  2 PLACE  .XX:  

 .01  [0.3]

  3 PLACE  .XXX: 

 .005  [0.13]

BR42887

THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR

RESIDENTIAL FILTRATION, LLC.  REPRODUCTION, USE 

DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR

DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS 

PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR 

RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS 

DOCUMENT AND ANY COPIES SHALL BE RETURNED TO

PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.

  COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS

TOP VIEW

Reviews: