background image

2

Before Operation:

Read the following instructions
carefully. Reasonable care and
safe methods should be 
practiced. Check local codes and
requirements before installation.

Attention:

This manual contains important
information for the safe use of
this product.  Read this manual
completely before using this
product and refer to it often for
continued safe product use.
DO NOT THROW AWAY OR
LOSE THIS MANUAL.  Keep it
in a safe place so that you may
refer to it often.

Warning:

Before handling these pumps and
controls, always disconnect the
power first. Do not smoke or use
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.

CAUTION AND WARNING

Important Safety
Instructions

Rules for Safe Installation and
Operation

1. READ THESE RULES AND 

INSTRUCTIONS CAREFULLY.
Failure to follow them could
cause serious bodily injury
and/or property damage. 

2. Check local plumbing and 

electrical codes before
installing. You must comply
with those rules.

3. Battery box must be kept in a

cool, dry, well ventilated area.

4. Battery must not be exposed 

to any sparks or flames. An
explosion or fire could result.

5. Battery acid is very corrosive;

avoid spilling on skin or 
clothing. Eye protection must
be worn when handling the 
battery.

6. Battery Selection and

Maintenance

Use a new 12 volt, fully

charged battery with top 
terminals. For maximum 
performance and battery life, a
deep cycle (marine, group 24,
min. 105 AH) battery should be
used. 

• The electrolyte level should

be checked monthly and filled
as required. Automotive 
batteries may be used but
a slight decrease in 
performance and battery life
will result.

• Group 24 batteries will fit 

into the battery box with 
maximum battery dimensions
of 12" long x 6-1/2" wide x
9" high to the top of the 
terminals.

• Replace the battery if the

back-up pump operated for an
extended period of time and
the battery is severely
discharged. It is also 
recommended that the battery
be replaced every three years
even if the system is not used.

General
Information

FG-A1 and
Pump Warning

7. When service is required,

proceed carefully:

Disconnect the power at the
main electrical service box by
turning the circuit breaker off
or by removing the fuse.

Disconnect the battery 
charger from the wall after 
the power is disconnected.

DO NOT

lift the pump by the

cord.

8.  To be used only as a back-up 

sump pump in residential 
waste water applications. 

DO NOT

run the pump dry.

Summary of Contents for FG-A1

Page 1: ...Back Up Power Supply FG A1 NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Unit Installation and Service Manual ...

Page 2: ... fire could result 5 Battery acid is very corrosive avoid spilling on skin or clothing Eye protection must be worn when handling the battery 6 Battery Selection and Maintenance Use a new 12 volt fully charged battery with top terminals For maximum performance and battery life a deep cycle marine group 24 min 105 AH battery should be used The electrolyte level should be checked monthly and filled a...

Page 3: ...y indicator light will come on and the buzzer sounds for the ALARM function Battery should be checked by a battery shop 5 Assemble back up pump a minimum of 1 above the primary pump and tilt 30 per Figure 1 below The enclosed pump includes a built in check valve and screws directly into the side of the tee included The other two ends of the tee will accept 1 1 4 or 1 1 2 PVC and ABS pipe An additi...

Page 4: ... reaches the bottom of the back up pump If not raise the float switch slightly Press the RESET and plug the primary sump pump back in Note Be sure that there is a 4 minimum from the top of the back up pump to the top of the sump The float switch should turn this pump ON near the top of the pump and at least 2 down from the top of the sump CONTROL PANEL BATTERY BOX BATTERY CHARGER RIGID 1 1 4 or 1 ...

Page 5: ...e of the battery drops lower than 11 volts DC the LOW battery indicator will come on and the buzzer will sound if the ALARM switch is in the ON position At this time the battery should be checked and serviced or replaced The only real test for a battery is when it is tested with a load meter Take the battery back where it was purchased for the test The CHARGING indicator will come ON when the batt...

Page 6: ...backup pump activated and drained the tank The alarm activates any time the pump is called to operate It continues to operate until the alarm condition is manually acknowledged by pressing the reset switch Q Pressing the reset switch didn t silence the alarm Now what A The alarm circuit is activated so long as the float switch is activated Check to see if the backup float switch is tangled or caug...

Page 7: ...sump pump be used with a pedestal sump pump A Yes However your sump basin must be at least 18 in diameter and an additional piece of PVC pipe must be used to extend the pump tee so the backup pump will not interfere with the float rod of the pedestal pump Q The pump is buzzing but not pumping What s wrong A There are several reasons why this situation might occur A The system is air locked Make su...

Page 8: ...disposition Any transportation charges involved in such disposition shall be for the Buyer s account The Buyer s exclusive and sole remedy on account or in respect of the furnishing of material that does not conform to this contract or to this written warranty shall be to secure replacement thereof as aforesaid Hydromatic shall not in any event be liable for the cost of any labor expended on any s...