background image

KEYSTONE

Hygienic butterfly valves model F250 & F251

Installation & Maintenance Instructions

Pentair reserves the right to change the contents without notice 

EBPJV-0765-EN-1305

1  

Contents

1 Contents 

1

2 Introduction 

1

2.1 

Valve use 

1

2.2. 

Application area 

1

2.3. 

Incorrect use 

1

3. Safety 

2

4. 

Transport and storage 

2

5. 

Installation instructions 

2

5.1. Mounting 

2

5.2. 

Installation into pipe work 

2

6. 

Cleaning and maintenance 

2

6.1. Cleaning 

2

6.2. Lead-time 

2

6.3. 

Safety measures during maintenance 

2

6.4. 

Grease to be used 

2

6.5. 

Disassembling the butterfly valve 

2

6.6. 

Disassembling the wafer style butterfly valve 

3

6.7. 

Assembling the butterfly valve 

3

6.8. 

Assembling the wafer style butterfly valve 

3

6.9. Failures 

3

Appendix A - Technical specifications 4

Butterfly valve ordering code 

4

Butterfly valve material 

4

Seat and flange seal material 

4

Liquid operating pressure 

4

Operating temperature 

4

Air supply actuator F257 

4

Appendix B - Assembly drawing F250 & F251 

5

Parts and spare parts 

5

Ordering (spare) parts 

5

Appendix C - Assembly drawing F250 & F251 wafer style 

6

Parts and spare parts 

6

Ordering (spare) parts 

6

Appendix D - Actuator F257 

7

Mounting parts 

7

Actuator mounting 

7

2 Introduction

2.1  Valve use

The Keystone F250 and F251 hygienic butterfly valves are universal valves for manual or automated 
isolation and control.

2.2 Application area

The butterfly valve has been designed for use in the food & beverage, pharmaceutical and light 
chemical industries.

2.3 Incorrect use

The butterfly valve is not suitable for use in gas systems.
Liquids with hard solid parts cause increased wear to the seat.

www.pentair.com/valves

Summary of Contents for F251

Page 1: ...3 Appendix A Technical specifications 4 Butterfly valve ordering code 4 Butterfly valve material 4 Seat and flange seal material 4 Liquid operating pressure 4 Operating temperature 4 Air supply actuat...

Page 2: ...resistant to detergents that are commonly used in the food industry such as a lye NAOH or acid HNO3 solution of about 2 at a temperature of about 80 C After cleaning the system must be rinsed with cl...

Page 3: ...t body screws 16 and nuts 17 tighten to recommended torque s Valves DN 25 to DN 65 14 Nm DN 80 to DN 150 19 Nm E Place flange seals 15 F Place the valve between the flanges 14 G Wind two of the inside...

Page 4: ...r metal parts are made of stainless steel W Nr 1 4301 The bearings are made of POM Seat and flange seal material The seat can be made of VMQ white FDA EPDM black FDA NBR black FDA FPM red The flange s...

Page 5: ...2 Body half W Nr 1 4404 2 1 Seat VMQ EPDM NBR or FPM X 3 1 Disc W Nr 1 4404 4 2 Bearing POM X 5 1 Notch plate W Nr 1 4301 6 1 Handle Polymer or W Nr 1 4301 7 1 Spring washer A2 8 1 Handle screw A2 9...

Page 6: ...or FPM X 3 1 Disc W Nr 1 4404 4 2 Bearing POM X 5 1 Notch plate W Nr 1 4301 6 1 Handle Polymer or W Nr 1 4301 7 1 Spring washer A2 8 1 Handle screw A2 9 1 Plug Nylon 10 4 6 Bolt A2 11 4 6 Nut A2 12 2...

Page 7: ...ndicate open or closed position B Remove handle if fitted see 6 5 C Fit drive boss 18 onto the valve stem square so that the actuator will be correctly orientated D Position the actuator onto the valv...