EVOLIO-560 SOFTENER SPECIFICATIONS

Characteristics

EVOLIO-560 8 EVOLIO-560 15 EVOLIO-560 20 EVOLIO-560 30

Resin liters (L)

8

15

20

30

Nominal flow 

rate (m³/h)* 
@10°f

0.42

0.6

0.8

1.2

Peak flow rate 

(m³/h)* @10°f

0.83

1.56

2.08

3.12

Exchange 
capacity (°f/m³)

40

75

100

150

Salt 

consumption 

per regen. (kg)

0.96

1.8

2.4

3.6

Approx. water 
consumption 

per regen (L)**

47

83

189

279

Salt storage (kg)

25

50

50

50

Width (cm)

31

31

31

31

Depth (cm)

42.5

42.5

42.5

42.5

Height (cm)

76

120

120

120

Approx. ship 

weight (kg)

12

20

30

35

Note: All calculations are based on a salt dosage setting at 120g/l of resin. The softener 
installation takes into account a pre-filter made of a 10” filter housing (Pentair ref. 
150543) and a 10” 100micron Wound cartridge (Pentair ref. WWP100P10).

* Indicative data. Maximum flow rate to produce in order to respect the  required service 

velocity for an optimal ion  exchange upon resin manufacturers recommendation, 
regardless of the  inlet pressure.
** Values may vary upon local condition and programming. All consumptions are given 
for an inlet pressure of 3.44 bar (50 psi).

GENERAL PRECAUTIONS

Before you begin installation, read the entire manual. Gather 

all materials and tools needed. Improper installation voids 

warranty.

 WARNING

Do not use with water that is microbiologically 

unsafe or of unknown quality without adequate 

disinfection before or after the softener.

 WARNING

SODIUM INFORMATION: Water softeners using 

sodium chloride for regeneration will add sodium 

to the water. Persons who are on sodium-

restricted diets should consider the added 

sodium as part of their overall sodium intake.

NOTE: Sodium Chloride or Potassium Chloride are 

recommended for regeneration.

NOTE: The efficiency of this softener shall be valid only at the 

stated salt dosage calculation is made on 120g.

RECOMMENDATION: We recommend that a qualified plumber 

be contracted to make all difficult piping installations. 

CAUTION:

Softener must be protected against freezing, which 

can cause cracking of the softener and water 

leakage.

CAUTION:

Do not treat water over 43°C because hot water 

will damage the softener and void warranty.

CAUTION:

Locate the softener within 500 cm of drain.

Drain must be capable of handling a maximum 

backwash flow rate of 19 liters of water per minute.

PRE-INSTALLATION CHECKLIST

Installation by a licensed plumber is recommended.
1.  Valves, grounding straps, wire, clamps and wall pipe, are 

not supplied with the water softener.
NOTE: Ball or globe valves are recommended.

2.  Electrical Requirements: AC 220V, 50 or 60HZ current 

supply is required.

CAUTION:

Make certain the electrical supply cannot be turned 

off accidentally.

3.  Location of Softener and Drain: We recommend that the 

softener be installed on a sound plumbing system within 

500 cm from the drain.
NOTE:  Outside faucet should be bypassed and left on 

hard water.

4.  Bypass Valves: Bypass valves allow you to turn off the 

water to your unit but not the water service to your home.

Figure 2 

5.  Pre-Filtration: To prevent your softener from incoming 

sediment and iron particles we recommend the installation 

of a pre-filter on the water line going to the unit

INSTALLATION

RECOMMENDATION: We recommend that a qualified plumber 

be contracted to make all difficult piping installations. 

1.  SHUT OFF FUEL SUPPLY TO WATER HEATER. See 

manufacturer’s instructions.

2.  Shut off all water at main supply valve.
3.  Open faucet nearest pump or water meter to relieve 

pressure and drain system.

CAUTION:

The water filter system should be installed 

with the inlet, outlet and drain connections 

made in accordance with the manufacturer’s 

recommendations and to meet applicable 

plumbing codes.

4. 

Set the water filter in place.Place in a firm concrete floor or 

slab base. Be sure unit is reasonably level.
NOTE:   Do not shim the tank directly for leveling. If 

necessary to shim, fabricate a platform base to 

set the tank on and then shim under the platform 

base.

5.  Shut off the water to the home. Open the highest faucet 

in the plumbing system and then the lowest (you cannot 

work on pipes with water in them). Make necessary piping 

changes for connection of the filter to the plumbing of the 

home (see Figure 5).EVOLIO-560 softeners are suplied 

with 1”BSP connection

6.  It is highly recommended that the bypass valve accessory 

be installed

Make certain the untreated water piping connects to 

the control valve on the right and the softened water is 

connected on the left (Figure 4).

Figure 4 

7.  Connect the inlet and outlet piping. The valve connection 

threads are 1” BSP. Be sure you have the incoming water 

connected to the right side (Figure 4). 
NOTE:   Do not use pipe joint compound or plumber’s 

putty on the backplate threads. Use only Teflon

®

 

Tape.

NOTE:   Do not over-tighten fitting to backplate.

8.  Make certain proper piping alignment is maintained. Do 

not apply heat to any fitting connected to the conditioner or 

damage to the valve may occur.

9. 

Move conditioner into position and level. Check all 

connections for tightness. 

CAUTION:

To prevent water leaks, connections to softener 

must be straight when the tank is leveled

CAUTION:

Review Drain Requirements section before 

connecting drainlines.

10. Carefully attach valve drain line to drain on the back of the 

valve.

CAUTION:

Do not raise drain line over 2m from floor

Out 

In 

Yoke

CAUTION:

Maximum allowable inlet water pressure is 

8 Bars if daytime pressure is around 8 Bars, 

nighttime pressure may exceed the maximum. 

Use a pressure-reducing valve if necessary. Use a 

pressure-reducing valve if necessary. 

NOTE: Handle softener with care. Do not turn upside down, 

drop, or set on sharp objects.

NOTE: The valve requires a minimum inlet pressure of 2 Bar 

at 1.2 m

3

/h.

NOTE: If you are on a private well system, check minimum 

water pressure with an accurate gauge. (Gauges on 

older water systems are often inaccurate). Pressure 

that is less than 2 Bar may cause low flow rate and 

inadequate regeneration, but depending by the 

pressure droop of the system.

CAUTION:

When connecting your unit, take note that the 

inlet, outlet, and drain connections are made in 

accordance with state and local plumbing codes.

CAUTION:

Do not over-tighten pipe to piping boss.

CAUTION:

Due to some homes using piping as a source of 

electrical grounding, a grounding strap must be 

installed where required.

CAUTION:

Do not heat piping if it is in contact with the control 

valve.

NOTE: Do not put excessive force on the inlet/outlet drain 

connections of the control valve. 

NOTE: Do not use pipe joint compound or plumber’s putty 

when threading pipe into the piping boss. Use only 

Teflon

®

 Tape. 

 WARNING

Do not use any chemical substance (out off 

suggested in Pg. 6) to clean resin or softener 

component with out the approval of the producer 

Electrical Precautions

 WARNING

The unit must be plugged into an outlet. 

 WARNING

Do not use any extension cords.

 WARNING

Locate cord where it cannot be accidentally 

unplugged or cause any bodily harm. 

 WARNING

Electrical components are not waterproof. 

CAUTION:

Make sure power source matches the rating on 

the unit. 

CAUTION:

Make certain the electrical supply cannot be 

turned off accidentally. 

NOTE: The outlet you select must not be controlled by a wall 

switch. 