Pentair EVERPURE Insurice PF Series Instructions Download Page 2

 2 

INSURICE PF SYSTEMS INSTALLATION AND OPERATION GUIDE

OPERATING SPECIFICATIONS*

Combined 

Model Name

Replacement 

Cartridges

Flow Rate

Capacity

Insurice PF 

Single - i2000

i2000

1.67 gpm  

(6.3 Lpm)

9,000 gal (34,050 L)

Insurice PF 

Single - i2000

2

i2000

2

1.67 gpm  

(6.3 Lpm)

9,000 gal (34,050 L)

Insurice PF 

Twin - i2000

i2000

3.3 gpm  

(12.6 Lpm)

18,000 gal (68,100 L)

Insurice PF 

Twin - i2000

2

i2000

2

3.3 gpm  

(12.6 Lpm)

18,000 gal (68,100 L)

Insurice PF 

Triple - i2000

i2000

5.0 gpm  

(18.9 Lpm)

27,000 gal (102,150 L)

Insurice PF 

Triple - i2000

2

i2000

2

5.0 gpm  

(18.9 Lpm)

27,000 gal (102,150 L)

Insurice PF 

Single - i4000

i4000

1.67 gpm  

(6.3 Lpm)

12,000 gal (45,400 L)

Insurice PF 

Single - i4000

2

i4000

2

1.67 gpm  

(6.3 Lpm)

12,000 gal (45,400 L)

Insurice PF 

Twin - i4000

i4000

3.3 gpm  

(12.6 Lpm)

24,000 gal (90,800 L)

Insurice PF 

Twin - i4000

2

i4000

2

3.3 gpm  

(12.6 Lpm)

24,000 gal (90,800 L)

Insurice PF 

Triple - i4000

i4000

5.0 gpm  

(18.9 Lpm)

36,000 gal (136,200 L)

Insurice PF 

Triple - i4000

2

i4000

2

5.0 gpm (18.9 Lpm) 36,000 gal (136,200 L)

*For individual cartridge specifications, refer to cartridge literature.

Temperature: 

35-100°F (2-38°C)

Pressure:  

10-125 psi (0.7-8.6 bar), non-shock

For cold water use only.

INSTALLATION

1.  Use the predrilled mounting holes in the manifold bracket 

as guides. Mark and drill anchor hole. Mount securely.

2.  Shut off power to ice machine.
3.  Connect outlet port of the Insurice PF system to 

equipment served. Always use a NSF approved pipe dope 

or plumber tape at all connections. Use a backup wrench 

on all fittings while connecting to avoid excessive stress 

on the system components.

4.  Connect minimum 1/2-inch (3/4-inch prefered) water 

line to the inlet side of the Insurice PF System prefilter. 

Do not turn on the supply water yet.

5.  Connect tubing to flushing valve and run to drain. 

NOTE: Some municipal plumbing codes 

and good sanitary practices 

require an air gap at the drain 

termination point.

Air Gap

6.  Remove the wrapping from the prefilter cartridge and 

insert it into the clear prefilter bowl, aligning the hole in 

the bottom of the cartridge over the raised stub in the 

bottom of the bowl.

7.  Check to see that the o-ring is in place at the top of the 

prefilter bowl and that it is lubricated with food grade 

silicone lubricant. Install the bowl by aligning the hole 

in the top of the cartridge with the stub extending down 

from the housing head and threading the bowl onto the 

head. Hand tighten snugly. Do not over-tighten the bowl.

8.  Remove the wrapping from the Insurice PF  

filter cartridge(s).

9.  Install the Insurice PF cartridge(s) into the Insurice PF 

system head(s) following directions on the cartridge 

label or as shown in the Cartridge Change Procedure 

section illustrations.

10. Turn on water supply and flush the cartridge(s) by 

running water through at full force for five minutes. 

This will set the filtering media and purge air and fines, 

ensuring maximum filter life.

11. After flushing, close the flushing valve and turn on power 

to equipment. 

CARTRIDGE CHANGE DETERMINATION

Replace cartridges when capacity is reached, or when flow 

becomes too slow, but at least annually.
The system outlet pressure gauge provides a quick, simple 

means of determining when the Insurice PF filter cartridge(s) 

should be checked. The gauge can be used to monitor 

dynamic (flowing) pressure and static (line) pressure. The 

filter cartridges should be changed when the gauge needle 

is in the red area while the system is in operation. In multiple 

cartridge systems, all filter cartridges should be changed at 

the same time.

CARTRIDGE CHANGE INSTRUCTIONS

1.  Shut off the inlet water supply to the system.
2.  Make sure any outlet valves to equipment are closed.
3.  Connect a drain hose to the flushing valve or place a 

bucket under its outlet.

4.  Open the flushing valve to relieve system pressure.
5.  Momentarily depress the red pressure relief valve 

buttons on top of the prefilter head.

6.  Unthread and remove the clear prefilter bowl and dump 

any water from the bowl. A sump wrench is provided to 

assist in loosening a tight bowl. Remove and discard the 

old prefilter cartridge.

7.  Rinse and clean the bowl with clean water. No special 

cleaners are needed.

8.  Check and clean the bowl o-ring. If it is dry, lubricate it 

with a food grade silicone lubricant. If it is cracked or 

deteriorated, replace it.

Summary of Contents for EVERPURE Insurice PF Series

Page 1: ...ance are improved while machine downtime maintenance and energy costs are substantially reduced See individual product specification sheets for performance claims and FIFRA registration information SELECTING A MOUNTING LOCATION 1 Give consideration to the weight of the unit when operating filled with water Operating weights of the Insurice PF systems are Single System 19 lbs 8 62 kg Twin System 35...

Page 2: ...e raised stub in the bottom of the bowl 7 Check to see that the o ring is in place at the top of the prefilter bowl and that it is lubricated with food grade silicone lubricant Install the bowl by aligning the hole in the top of the cartridge with the stub extending down from the housing head and threading the bowl onto the head Hand tighten snugly Do not over tighten the bowl 8 Remove the wrappin...

Page 3: ...ws and regulations Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Not for residential use For food service applications only REPLACEMENT PARTS Contact your local Pentair Everpure dealer for filter cartridges ...

Page 4: ...d notify Pentair Everpure technical service at the phone number listed below Any part found materially defective within the terms of this warranty will be repaired or replaced at PFS s discretion by your local dealer or Pentair Everpure technical service You pay only freight from our factory and local dealer charges Any item repaired or replaced pursuant to this warranty will be covered under the ...

Reviews: