background image

English

LOCATION AND MOUNTING

1.  Hoffman electric heaters should be centered as low as possible in the enclosure for 

optimum heat distribution.

2.  It is recommended that the heater be installed on a non-combustible metal panel for 

optimum performance. It may, however, be mounted on any metal surface.

WARNING: Heaters must not be installed on wood or other combustible surfaces.

3.  The heater should be mounted in a vertical position with the terminal block at the 

bottom and the air outlet openings at the top as shown.

4.  The recommended clearances shown by the shadowed area indicates the space that 

should be kept free of components for safe operation of the heater.

WARNING: Heat sensitive components must not be placed above the heater discharge 

area.

5.  Four 10−32 UNF, self−tapping screws are included for installation.

Vertical Surface Mounting

Optional Horizontal Surface Mounting

Watts

X

D

E

DAH1001A, DAH1002A

100

4

5.00 (127 mm)

3.25 (83 mm)

DAH2001A, DAH2002A

200

6

DAH4001B, DAH4002B

400

6

7.00 (178 mm)

3.50 (89 mm)

DAH8001B, DAH8002B

800

8

DAH13001C, DAH13002C

1300

8

© 2012 Pentair Technical Products

- 3 -

PH 763 422 2211  •  hoffmanonline.com

87565511

Summary of Contents for DAH1001A

Page 1: ...Electric Heaters 2012 Pentair Technical Products PH 763 422 2211 hoffmanonline com 87565511 Rev D P N 28359001 ...

Page 2: ...ls 2 If continuous operation of the heater is essential to the safe functioning of any other equipment adequate warning devices must be installed to assure safe operation at all times Do not use these electric heaters in dusty dirty corrosive or hazardous locations Reduce the thermostat from factory setting to a recommended setting not to exceed 75 F for most applications Portions of the heater ca...

Page 3: ...d the air outlet openings at the top as shown 4 The recommended clearances shown by the shadowed area indicates the space that should be kept free of components for safe operation of the heater WARNING Heat sensitive components must not be placed above the heater discharge area 5 Four 10 32 UNF self tapping screws are included for installation Vertical Surface Mounting Optional Horizontal Surface ...

Page 4: ...r housing SETTING THE THERMOSTAT 1 The heater is controlled by an adjustable thermostat Set the thermostat to the desired temperature It is recommended not to exceed 75 F for most applications MAINTENANCE 1 Always disconnect power supply before inspecting or working on the heater 2 Generally the unit requires no maintenance since the fan bearings are permanently lubricated and sealed Temperature R...

Page 5: ...English L1 N or L2 M T 100 800 Watt Schematic M L S L1 T N or L2 1300 Watt Schematic 2012 Pentair Technical Products 5 PH 763 422 2211 hoffmanonline com 87565511 ...

Page 6: ...Wiring Illustration 1 3 2 1 2 3 2012 Pentair Technical Products 6 PH 763 422 2211 hoffmanonline com 87565511 ...

Page 7: ...Notes 2012 Pentair Technical Products 7 PH 763 422 2211 hoffmanonline com 87565511 ...

Page 8: ...Notes 2012 Pentair Technical Products 8 PH 763 422 2211 hoffmanonline com 87565511 ...

Reviews: