C SERIES
®
Bronze Commercial Pump Installation Guide
3
Pump Curves
The following items are for Saudi Arabian export compliance only:
3 Phase, 60Hz, 380-400V Pumps IEC 602335-1 and 602335-2-41
Maximum Water Temperature = 40°C Non-Submersible Pump IP Rating: IP24
Wiring used for connection to pump must have a minimum wiring insulation rating of 90°C.
Motor HP
Maximum Total Head
5
25.00m
7.5
28.35m
10
31.10m
15
40.85m
20
42.07m
Pump Performance Curve
CH/CHK Series Pump
CH/CHK SERIES PUMP
60 CYCLE
3450 RPM
TO
TA
L
DY
NAMIC HEAD IN FEET OF
WA
TE
R
160
140
120
100
80
60
40
20
0
0
100
200
300
400
500
600
700
800
900 1000
FLOW-RATE IN GPM
CHK-200: 20 HP
CHK-150: 15 HP
CHK-100/CH-100: 10 HP
CHK-75/CH-75: 7.5 HP
CHK-50/CH-50: 5 HP
Pump Performance Curve
CM/CMK Series Pump
CM/CMK SERIES PUMP
60 CYCLE
3450 RPM
TO
TA
L
DY
NAMIC HEAD IN FEET OF
WA
TE
R
FLOW-RATE IN GPM
160
140
120
100
80
60
40
20
0
0
100
200
300
400
500
600
700
800
900
1000
CMK-50/CM-50: 5 HP
CMK-75/CM-75: 7.5 HP
CMK-100/CM-100: 10 HP
CMK-150: 15 HP