Pentair Pool Products Meteor Series Owner'S Manual Download Page 3

Rev. E  2-22-02

3

P/N  99223000

Section III.

Installation

To install this filter system, you will need the following simple tools: Screwdriver, pliers  and  ½ in. wrench.

1.

Carefully remove the equipment from the carton and check for any evidence of damage due to rough handling or shipping.
If any of the equipment is damaged, immediately notify the organization from where the equipment was purchased.

2.

Provide space and lighting for routine maintenance access. Locate the system in close proximity to the pool as listed in the
National Electrical Code or local electrical codes and any caution or warning labels on pump.

3.

One needs to be able to stand clear of the filter when starting the pump.

4.

This filter system should be mounted on a level concrete slab, preferably concrete poured in a form or on a platform
constructed of block or brick.

5.

Position the base in relationship to the return fitting and skimmer on your pool. Position the filter tank on the base. Place the
pump in the mounting position and align with the set of molded in nuts. Secure pump with 2 bolts.

6.

Media - Your sand filter uses a #20 grade silica filter sand for its media (.45 - .55mm). It should be free of all limestone or clay.
Most pool supply and building material stores carry silica sand. See Table 1 for the appropriate amounts of silica sand for your
filter.

7.

Install the sand guide in the top of the filter tank and fill the tank about half full of water. Pour the silica sand into the top of
the filter tank slowly, so that the weight does not damage the laterals in the bottom of the tank.

8.

After filling the filter tank with the appropriate amount of silica sand, remove the sand guide and wash away any loose sand
from the opening of the filter tank.

9.

Be sure that all sealing surfaces are clean on the filter tank and the valve.
Apply a light coating of silicone based lubricant to the gasket of the valve
and place the valve over the opening in the top of the filter tank so that the
center pipe slips into the bore of the valve.

10. Position the valve, (item #1 on page 7), so that the inlet port is facing the same

direction as the inlet port of the pump. Valve ports are labeled to insure proper
connections.

11. Install the valve clamp halves, (item #3 on page 7), over the flanges of the

filter tank and the valve. Ensure that the valve clamp halves are securely
installed over 

BOTH

 flanges before attaching and tightening the bolts.

Tighten both bolts until both clamp halves touch.

12. Attach hose assembly, (item #17 on page 7), to pump using the quick connect nut, (item #16 on page 7), on the bottom end of

assembly. Screw threaded elbow adapter, (item #15 on page 7), into inlet port of valve, using Teflon tape on threads, tighten a
max. of one turn past hand tight. Connect hose assembly to the adapter and secure with a hose clamp. Tighten the clamp with
a screwdriver.

13. Screw hose adapter, (item #19 on page 7), {included in hose kit}, into inlet port of pump, using Teflon tape on the threads and

tightening no more than one turn past hand tight. Connect flex hose to the adapter and secure with hose clamp. Attach other
end of flex hose to the skimmer on the pool wall. Use the adapter and hose clamp provided in the hose kit.

14. Screw hose adapter, (item in hose kit), into the outlet port of the valve, attach the second flex hose and secure with a hose

clamp. Connect the other end to an adapter screwed into the return fitting on the pool wall. Secure with a hose clamp.

15. Install the pressure gauge into the valve using Teflon tape.

16. Install clear sight glass fitting, called the backwash fitting into the control valve port marked backwash. An O-ring is provided

for sealing, requiring only hand tightening.  This sight glass is supplied with 1.5 in. NPT male thread on the outside end for
easy connection to a drain pipe.

17. To use 1½ in. flex hose for drain, connect the grey hose adapter to the end of the sight glass and secure the flex hose to the

barbed end of the adapter with a hose clamp.

DO NOT OPERATE THIS SYSTEM ABOVE MAXIMUM OPERATING PRESSURE OF THE VALVE OR FILTER.

Table 1.

Model

Max. Filtration

Amount

Area

of Sand

18" Meteor

1.63 sq. ft.

65-100 lbs.

20" Meteor

2.0 sq. ft.

100-150 lbs.

22" Meteor

2.5 sq. ft.

150-200 lbs.

This filter operates under pressure. With the valve clamped properly and operated without air in the system, this
filter will operate in a safe manner. Air entering the filter and the valve not clamped correctly can cause the valve to
be blown off, which could cause severe personal injury and/or property damage.

WARNING

Summary of Contents for Meteor Series

Page 1: ...951 West Los Angeles Ave Moorpark CA 93021 805 523 2400 Important Notice Attention Installer This manual contains important information about the installation operation and safe use of this product This information should be given to the owner operator of this equipment WARNING Before installing this product read and follow all warning notices and instructions accompanying this system Failure to f...

Page 2: ...r death Section II How Your Filter Works Your high rate sand filter is designed to produce clear sparkling water and operate for years with a minimum of maintenance when installed operated and maintained in accordance with these instructions Your filter uses special filter sand to remove dirt particles from the water Dirt is collected in the filter by the sand bed as water flows through the filter...

Page 3: ...labeled to insure proper connections 11 Install the valve clamp halves item 3 on page 7 over the flanges of the filter tank and the valve Ensure that the valve clamp halves are securely installed over BOTH flanges before attaching and tightening the bolts Tighten both bolts until both clamp halves touch 12 Attach hose assembly item 17 on page 7 to pump using the quick connect nut item 16 on page 7...

Page 4: ...aste Stand clear of filter and start the pump 5 Run the pump for at least two minutes 6 Turn the pump off and set valve to filter position Ensure that all pool suction and return lines are open so that water is free to flow from and to the pool Stand clear of filter and start the pump 7 Your filter has now started its filtering cycle You should check that water is returning to the pool and take no...

Page 5: ...of the filter and start pump 4 Backwash filter for approximately 3 5 minutes or until backwash water is clean 5 Turn off pump Set control valve back to rinse position 6 Stand clear of the filter and start pump 7 Rinsefilterforapproximately3 5minutes 8 Turn off pump Set control valve back to filter position 9 Stand clear of the filter and start pump 10 The filter has now started its filtering cycle...

Page 6: ...lter 3 Partially closed valve or restriction Openvalveorremoveobstructioninreturnline Short filter cycles 1 Improperbackwash Backwashuntileffluentrunsclear 2 Poolchemistrynotadequatetoinhibitalgaegrowth Maintainpoolchemistryorconsultpoolservicetechnician 3 Pluggedsandbed Manuallyremovetop1 surfaceofsandbedandchemicallycleanasrequired 4 Flow rate too high Restrict flow to capacity of filter Returnf...

Page 7: ...d base 18 filter 13 55215000 Skid base 20 22 filter 14 711004 Clamp hose 15 86201900 Adapter hose elbow 16 352256 Nut quick connect 17 86013000 Hose assy for 18 filter 17 86013090 Hose assy for 20 filter 17 86013100 Hose assy for 22 filter 17 79302100 Hose assy braided for 18 filter 17 79302200 Hose assy braided for 20 filter 17 79302300 Hose assy braided for 22 filter 18 354571 O ring 19 711006 A...

Page 8: ...e skimmer opening A low water level can cause the pump motor to run dry which will damage the mechanical seal and cause external leakage 3 Shaft Seal Rotary Seal The shaft seal consists of two parts a Stationary ceramic seal press fitted into seal plate b A rotating spring loaded seal press fitted onto impeller shaft CAUTION The highly polished and lapped faces of the seal are easily damaged Handl...

Page 9: ...Rev E 2 22 02 9 P N 99223000 This page is blank ...

Page 10: ...P N 99223000 10 Rev E 2 22 02 This page is blank ...

Page 11: ...Rev E 2 22 02 11 P N 99223000 This page is blank ...

Page 12: ...P N 99223000 12 Rev E 2 22 02 ...

Reviews: