Installation
Instructions

After taking the above
precautions, lower the 12V
battery into the enclosure with the
terminals facing the front of the
Unit where the indicator lights
and battery cables are located. At
this time check the polarity of
your marine battery. Facing the
front of the Unit, the left battery
terminal should be positive and
the right, negative. If this is not
the case do not continue until the
proper battery can be obtained.
(Do not try to correct this problem
in any other way than by using the
proper battery.)

Functions and Lights:

1. With the pump plugged into the power cord receptacle, the power

cord plugged into a building receptacle:

A.  Power loss (inverter on) light 

OFF

B.  Battery charging light 

ON

C.  Fully charged light

ON

2. With the pump plugged into the power cord receptacle, the power

cord plugged into a building receptacle, battery installed and 
connected, RECEPTACLE POWER ON:

A.

Power loss (inverter on) light 

OFF

B.

Battery charging light

ON

C.

Fully charged light 

OFF

D.

(If fully charged, light)

(ON)

3. With the pump plugged into the power cord receptacle, the power

cord plugged into a building receptacle, battery installed and
connected, RECEPTACLE POWER OFF:

A.

Power loss (inverter on) light 

ON

B.

Battery charging light

OFF

C.

Fully charged light 

OFF

D.

(If fully charged, light)

(ON)

4. AFTER EACH 5 MINUTES OF OPERATION, the Unit halts

inverter operation for 5 seconds to test for receptacle power, pump
stops: 

A.

Power loss (inverter on) light 

OFF

(may slowly dim)

B.

Battery charging light

OFF

C.

Fully charged light

OFF

D.  If receptacle power is found to be present, 

see # 2 above.

E.

If receptacle power is found to be off, 
see # 3 above.

5. If battery voltage falls below a usable charge, PUMP WILL STOP:

A.

Power loss (inverter on) light OFF

B.

Battery charging light 

FLASH

C.

Fully charged light 

OFF

6. Battery voltage may recover and allow brief periods of operation.

Now that the battery has been
installed with the terminals
nearest to the red and black wires,
PLUG THE UNIT INTO A 120V
OUTLET BEFORE CONNECTING
THE BATTERY LEADS. With
the Unit plugged into the 120V
outlet connect the battery leads to
the marine battery making sure
the red wire is connected to the
positive terminal and black 
wire is connected to the negative
terminal. Make sure all battery
connections are properly tightened
to 75 inch pounds. Then place the
battery box cover back on the Unit
and strap it down so that children
cannot tamper with the Unit. At
this time you may plug the high
efficiency pump supplied with the
System into the back of the
piggyback plug on the Unit. 

DO NOT PLUG ANY OTHER PUMP THAN THE PUMP
SUPPLIED WITH THE UNIT INTO THE UNIT.  DOING SO
WILL VOID THE WARRANTY!