11
11
6.
Use the provided female disconnect wire terminal to connect the “line” wire to the circuit
breaker tab marked “L”. The provided female disconnect wire terminal is shipped already
connected to the circuit breaker.
7.
Replace the electrical enclosure cover. With the tubs circuit breaker switch in the “OFF”
position, turn “ON” the circuit to the tub.
8.
Switch the tub’s circuit breaker to the “ON” position. The temperature gauges should
now display a temperature reading.
When the tub circuit breaker is turned on, if there is a sound like a running motor,
immediately
switch “OFF” the circuit breaker. Find the “Aqua-Aire” button on the control
panel of the tub and press it once. Switch on the tub circuit breaker. The motor should not be
running now.
Finishing up:
1.
Once the tub/reservoir has been connected to the drain, checked for leaks (and fixed if
needed), and is connected to power, the access doors can be installed.
Warning!
Do not
attempt to operate this equipment before selected personnel are trained in its
operation per the operation manual. The use of this equipment before inspection, adjustment,
and training per the operation manual could result in damage to the equipment or injury to
the operator and/or resident.
CAUTION