background image

Warranty

Model Numbers Covered:

 All PUCF Mod-

els

This warranty covers the Penguin Water
Non-Electric Upflow Carbon Filter.

This warranty cannot be transferred - it is
extended only to the original purchaser or
first user of the product in a residential ap-
plication. By accepting this product, you
agree to all the warranty terms and limita-
tions of liability described below. Important
Warning: Carefully read the Installation &
Operating Instructions Manual to ensure
safe and proper care of this product.

What is covered by this warranty?

  –

 The Penguin Water Dealer warrants that at
the time of manufacture, the water treat-
ment equipment shall be free from defects
in material and workmanship as follows:

Media is covered for three (3) years from
the date of purchase, not the date of in-
stallation. Tanks carry a Lifetime warran-
ty.

Additional Terms & Conditions

 –

 The Penguin Water dealer will, at its op-
tion, either make repairs to correct any de-
fect in material or workmanship or supply
and ship either new or used replacement
parts or products. Penguin Water will not
accept any claims for labor or other costs,
including subsequent or consequential
damages.

Additional Exclusions and Limitations

 -

This warranty is non-transferable and does
not cover any failure or problem unless it
was caused solely by a defect in material or

workmanship. In addition, this warranty
shall not apply:

• If the water treatment equipment is not

correctly installed, operated, re-
paired, and maintained as described in
the Installation & Operating Manual
provided with the product.

• Defects caused as a direct result of the

incoming water quality.

• To any failure or malfunction resulting

from abuse (including freezing), improper
or negligent; handling, shipping (by any-
one), etc.

• If the unit has not always been operated

within the factory calibrated temperature
limits, and at a water pressure not ex-
ceeding 100 psi, storage, use, opera-
tion, accident: or alteration, lightning,
flooding or other environmental condi-
tions.

• This warranty does not cover labor costs,

shipping charges, service charges, deliv-
ery expenses, property damage, adminis-
trative fees or any costs incurred by the
purchaser in removing or reinstalling the
water treatment equipment.

• The warranty does not cover any claims

submitted to The Penguin Water Deal-
er more than 30 days after expiration of
the applicable warranty.

THESE WARRANTIES ARE GIVEN IN
LIEU OF ALL OTHER EXPRESS WAR-
RANTIES. NO PENGUIN WATER DEAL-
ER OR ANY OTHER PARTY IS AUTHOR-
IZED TO MAKE ANY WARRANTY OTHER
THAN THOSE EXPRESSLY CONTAINED
IN THIS WARRANTY AGREEMENT.

15

Summary of Contents for 117-PUCF Series

Page 1: ...Penguin Water Non Electric Upflow Carbon Filter 117 PUCF XX...

Page 2: ...fety Guide 3 Penguin Chemical Removal Filter 4 Benefits 4 Four Step Treatment Process 4 Before Starting Installation 5 Proper Installation 5 Specifications 6 System Dimensions 7 Plumbing View 8 Instal...

Page 3: ...small parts will be in a parts bag inside the box carton It is suggested to keep the small parts in the bag until you use them Safety Guide Check and comply with your provincial state and local codes...

Page 4: ...the water these chemicals can no longer vaporize or evaporate in your shower steam Who would have thought that improving your water would also im prove your indoor air quality Healthier Skin By reduci...

Page 5: ...se distortion or other damage to non metallic parts Maximum allowable inlet water pressure is 100 psi If daytime pressure is over 80 psi night time pressure may exceed the maximum Use a pressure reduc...

Page 6: ...rop 8 GPM 12 GPM 16 GPM Approximate Flow Rate 25 PSI Pressure Drop 10 GPM 15 GPM 20 GPM Dry Weight lbs 40 47 65 Service Weight lbs 90 115 175 Electrical Requirements No Electricity Needed Water Pressu...

Page 7: ...System Dimensions Dimensions PUCF 10 PUCF 15 PUCF 20 A 52 5 58 5 56 5 B 50 56 54 C 9 10 12 D 2 5 2 5 2 5 7...

Page 8: ...Plumbing View 8...

Page 9: ...ly around the hole to ensure it is well distrib uted in the tank and pour slow enough to keep from plugging the hole Then proceed to pour the media labeled as Bag 2 KDF and repeat with the bags labele...

Page 10: ...t in place Place the upper basket over the distributor tube and push the head on the tank Thread the head on the tank by turning it clock wise Be sure not to cross thread the head on the tank 9 Place...

Page 11: ...e elbow connector Push the split white ring down over the elbow fitting to the second groove Use the supplied silicone grease to lubricate the O ring Slide the O ring over the elbow fitting and put it...

Page 12: ...nuts The bypass will move slightly once tight It is made to flex and move and will not be rigid Be sure the O rings are lubricated on the elbow connectors previously assembled Install the elbows in th...

Page 13: ...low the tank to fill with water Close the supply valve when a steady stream of water comes out of the outlet port and the water is running clear 14 Once the Non Electric Upflow Carbon Filter system is...

Page 14: ...Maintenance Schedule Media Pack Gravel KDF Catalytic Granular Activated Carbon Granular Activated Carbon Replace every 5 7 Years 14...

Page 15: ...tions This warranty is non transferable and does not cover any failure or problem unless it was caused solely by a defect in material or workmanship In addition this warranty shall not apply If the wa...

Page 16: ...al contingent or consequential dam ages Special incidental contingent and consequential damages for which the Pen guin Water Dealer is not liable include but are not limited to inconvenience loss or d...

Reviews: