Rev. 1.0
Penguin Computing
13
Disposal of this equipment should be in accordance with all national laws and
regulations.
15. Local and National Electrical Codes
This equipment should be installed in compliance with local and national
electrical codes.
16. Installation Codes
This device must be installed according to the latest version of the country
national electrical codes. For North America, equipment must be installed in
accordance to the applicable requirements in the US National Electrical Code
and the Canadian Electri-cal Code.
17. Battery Replacement
Warning: Replace only with UL Recognized battery, certified for maximum
abnormal charging current not less than 4mA.
There is a risk of explosion if the battery is replaced with a battery of an
incorrect type.
Dispose of used batteries according to the instructions.
18. UL Listed and CSA Certified Power Supply Cord
For a North American power connection, select a power supply cord that is
UL Listed and CSA Certified, 3-conductor, [16 AWG], terminated with a
molded plug rated at 125 V, [13 A], with a minimum length of 1.5m [six feet]
but no longer than 4.5m.
For European connection, select a power supply cord that is internationally
harmonized and marked “<HAR>”, 3-conductor, minimum 1.0 mm2 wire,
rated at 300 V, with a PVC insulated jacket. The cord must have a molded
plug rated at 250 V, 10 A.
19. Installation codes
This device must be installed according to the latest version of the country
national electrical codes. For North America, equipment must be installed in
accordance to the applicable requirements in the US National Electrical Code
and the Canadian Electrical Code.