background image

Part #501003-001

Product Manual:

Model #TFAT-14C

Telescopic Fall Arrest Tower

T.A. Pelsue Company

2500 South Tejon Street
Englewood, Colorado, USA  80110
Tel. 800-525-8460 or 303-936-7432 
Fax. 303-934-5581
Internet: www.pelsue.com  
Email: [email protected]

I S O   9 0 0 1   C e r t i f i e d

Summary of Contents for TFAT-14C

Page 1: ... Model TFAT 14C Telescopic Fall Arrest Tower T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Tel 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ISO 9001 Certified ...

Page 2: ... 501003 001 Product Manual Model TFAT 14C TELESCOPING FALL ARREST TOWER Revision 00 Date 06 16 2008 Page 2 ...

Page 3: ...ed a continuing reputation for excellence in the production of fine products for a broad spectrum of industry throughout the world Now in our second generation of family direction continued commitment to innovation and quality makes Pelsue a leading source of equipment for many types of confined spaces We specialize in safety retrieval fall arrest ventilation cable placing splicing and maintenance...

Page 4: ...on 7 2 1 Serial Number 3 0 Configuration Assembly 8 3 1 Label Locations 4 0 Safety 10 4 1 Warning Statement 4 2 Safety Alert Symbol 4 3 General Safety Information 4 4 Operating Safety 4 5 Maintenance Safety 4 6 New Operator Safety Information 5 0 Product Operation 13 5 1 Product Description Capabilities 5 2 Product Installation Set Up 6 0 Maintenance Inspection 18 6 1 Maintenance 6 2 Inspection 6 ...

Page 5: ...TOMER SATISFACTION IS ONE OF THE DIFFERENTIATORS THAT SETS YOU APART FROM THE PACK AND YIELDS A COMPETITIVE ADVANTAGE THEREFORE WE WILL SUPPORT TOTAL CUSTOMER SATISFACTION BY IMPLEMENTING THE ISO 9001 QUALITY SYSTEM AND PROVIDING THE NECESSARY ATMOSPHERE AND TRAINING TO NURTURE THIS CONCEPT THROUGHOUT OUR ORGANIZATION WE WILL MAKE EVERY BUSINESS DECISIONAS THOUGH THE QUALITY OF THE PART OR SERVICE...

Page 6: ... be covered by this warranty Unless otherwise agreed the T A Pelsue Company shall repair or replace the defective components within 30 calendar days of notice of failure T A Pelsue Company s obligation hereunder shall be limited to the repair or replacement of the product or component as set forth above and shall not include any liability whatsoever for damages caused by such failure including but...

Page 7: ...find specific information Keep this manual available for future reference and for usage as a tool in the instruction of new operators Establish a regular training program for all operators Establish a regular maintenance and inspection program to keep the equip ment in top condition This product is a part of a complete Fall Arrest System The user must read understand and follow the instructions co...

Page 8: ... the handles from the handle shaft by turning it counter clockwise 3 Once one handle is removed from the shaft pull on the other handle to extract the remaining handle shaft from the middle weldment 4 Slide the middle weldment into the lower section while aligning the handle hole in the middle weldment with the machined slot in the lower assembly 5 Insert the shaft handle assembly through the slot...

Page 9: ...t Manual Model TFAT 14C TELESCOPING FALL ARREST TOWER Revision 00 Date 06 16 2008 Page 9 Figure 3 1 TFAT 14C Label Locations 1 2 3 4 5 1 500984 001 2 500973 001 3 500985 001 4 500234 001 5 103299 001 3 1 Label Locations ...

Page 10: ...ety and operating practices while using the system Remember you are the key to safety Good safety practices not only protect you but also the people around you Make these practices a working part of your safety program Be certain that everyone operating this equipment is familiar with the procedures recommended and follows safety precautions Remember most accidents can be prevented Do not risk inj...

Page 11: ...nd know how to use it 5 Provide a fire extinguisher for use in case of an accident Store in a highly visible place 6 Install and properly secure all guards and shields before operating 7 Wear appropriate protective gear This list includes but is not limited to A hard hat Protective shoes with slip resistant soles Heavy gloves Protective clothing Face Protection 8 Review and follow the Pre Operatio...

Page 12: ... the area around the work site Untrained operators are not qualified to operate the equipment Many features incorporated into this equipment are the result of suggestions made by customers like you Read this manual carefully to learn how to operate install the equipment safely and as intended By following the operating instructions in conjunction with a good maintenance program your product will p...

Page 13: ...hich the tower base is installed is capable of withstanding the weight of the system combined with the system proof loads in order to retain the stated compliance of the entire system WARNING The user must ensure that the tower system is properly installed completely vertical in order to retain the stated compliance and stability of the entire system WARNING The user must ensure that the handles o...

Page 14: ...eveling Screws have not been damaged and are in working condition 5 1 Product Description Capabilities continued 5 2 Product Installation Set up Figure 5 2a TFAT 14C Series Pre Operation Inspection Points Leveling Screws Pin Base Plate Maximum Height Loading Diagram 310 LB 140 6 kg Maximum User Weight 20º 5 SAFE WORKING RADIUS All Heights Additional Requirements Notes The TFAT 14C Series Fall Arre...

Page 15: ... Plumb the TFAT 14C using the levelling pegs Refer to Fig 5 2c so that the structure is vertical and perpen dicular to the intended working surface 5 2 Product Installation Set up continued Figure 5 2c TFAT 14C Tower Vertical and Secured to Structure Figure 5 2b TFAT 14C Base Pin WARNING The Model TFAT 14C must be plumbed vertically prior to the attachment of any lifeline The TFAT 14C is only appr...

Page 16: ...t into the inverted J shaped slot Re Insert the T Handle pin thereby securing the composite tube to the TFAT 14C The composite tube may need to be rotated by hand in order to align the pin holes Once the pin si inserted the tower can be extended and secured in its upper most position using the two handles if maximum height is required d Asingle lifeline may now be attached to any of the three tie ...

Page 17: ...requires Instal lation within the 500019 001 Uni Lite Base Assembly Figure 5 2e TFAT 14C Installed secured at Mid Position 5 2 Product Installation Set up continued Detail C Anchorage Tie Off Rings Detail B Properly Secured T Handle Tower Anchoring Pin Detail A Handle Shaft Properly Secured in the inverted J Slot at the Mid Position WARNING The model TFAT 14C is only approved for the attach ment o...

Page 18: ...spection MAINTENANCE INSPECTION 6 0 Maintenance Inspection 1 Read understand and follow the Product Manual and all information located on the product before using maintain ing or inspecting the equipment 2 ANSI and OSHArequire a regular inspection program for all fall arrest equipment and to maintain documented results of these inspections Follow the inspection procedure contained in this manual a...

Page 19: ...are major dents or any other structural damage the unit should be removed from service and returned to the factory for evaluation and possible repair If there is any question as to the structural integrity of the product remove form service immediately and await further evaluation by a qualified organization or individual Pay attention to the bearing collars in the middle section Ensure that they ...

Page 20: ...ng Screws Overall Structure Notes Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Place a check in the box if item is acceptable place an x X in the box if item requires maintenance or repair Model Number Serial Number Date Purchased TFAT 14C ...

Page 21: ...2008 Page 21 6 3 Inspection Log continued Date Labels Pins Fasteners Leveling Screws Overall Structure Notes Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign ...

Page 22: ... on the frame and labels 2 Perform a complete inspection of the unit and document the results prior to storage 3 Oil or grease hinges and moving components in order to prevent corrosion 4 A TFAT 14C series system can be dismantled for storage if desired follow the reverse of the steps given for assembly in section 3 0 of this manual 7 0 Storage 8 0 Contact Information For More Information T A Pels...

Page 23: ... 501003 001 Product Manual Model TFAT 14C TELESCOPING FALL ARREST TOWER Revision 00 Date 06 16 2008 Page 23 ...

Page 24: ...ISO 9001 Certified T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Toll free 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ...

Reviews: