#501126-001 -
Product Manual: Model #BC-08A Adjustable Angle Beam Clamp
- Revision 00 - Date: 12-03-2009
Page 13
1. Pre-Operation Inspection:
It is necessary to perform a visual inspection prior to each time
using the product. If any deficiencies are found, remove the product
from service and contact the T.A. Pelsue Co. regarding repair. The
following checklist coupled with
Figure #5.2a
should be used as
a guide to determine whether the equipment is in good operating
condition prior to usage. Equipment that is not in good condition
can endanger the safety of the operators during use.
The Pre-Operation Visual Inspection is not limited to, but must
include the following items;
a.
Check that the product has no structural defects, such as dents,
bends, cracks, or fractures.
b.
Ensure that all product rating & warning labels are clear and
legible.
c.
Check that the track teeth mesh properly when tightening down
on the tightening nuts. (improper meshing can be indicative of
a defect).
d.
All hardware has not been damaged and is in working condi-
tion.
5.1 - Product Description & Capabilities (continued)
5.2 - Product Installation & Set-up
Prior to Operation, the #BC-08A Adjustable Angle Beam Clamp must be configured and installed according to the fol
-
lowing guidelines.
Figure #5.1c:
#BC-08A
Loading Diagram: Fall Arrest Tower
Mounting via Base Lugs
TEST LOAD
APPLIED AS
SHOWN
8930 ft.-lb. (static)
24,104 ft.-lb. (dynamic)
torsional proof loads
TEST LOAD
APPLIED AS
SHOWN
PROOF LOADS
APPLIED TO
FALL ARREST
TOWER (refer to #500714-
001, Product Manual, #FT-
C70)
Edge Mount
Top Mount
Figure #5.2a:
#BC-08A
Pre-Operation Inspection Points
Angle Tightening
Bolts
Track Teeth
Tightening Nuts
Track
Teeth
Base
Lugs
Base
Lugs
PROOF LOADS
APPLIED TO
FALL ARREST
TOWER (refer to #500714-
001, Product Manual, #FT-
C70)