Pelsue 115057-001 Product Manual Download Page 10

#115057-001 - Product Manual - Model #1400P Axial Ventilator 

- Revision 07 - Date: 03-28-2014

Page 10

The following section will address the safety precautions which must be adhered to when working with Pelsue confined 

Space Ventilation equipment such as the #1400P Axial Ventilator.  Any user must familiarize themselves with the infor-
mation in this section before utilizing the equipment.

SIGNAL WORDS:

Note the use of the signal words 

DANGer

WArNING

 and 

CAutION

 with the safety messages. The appropriate signal 

word for each message has been selected using the following guidelines:

D

ANGer- 

Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. This 

signal word is to be limited to the most extreme situations or for hidden or unseen hazards.

WArNING-

  Indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury and 

includes obvious and hidden hazards. It may also be used to alert against unsafe practices.

CAutION-

  Indicates a potentially hazardous situation that, if not avoided, may result in minor or moderate injury. It 

may also be used to alert against unsafe practices.

You are responsible for the safe operation of your Pelsue #1400P Axial Ventilator. You must ensure that anyone who will 

operate or work around the equipment be familiar with confined space ventilation procedures. This manual will take you 

step-by-step through the workings and capabilities of the #1400P Axial Ventilator and alert you to all good safety and 

operating practices while using the system.
Remember, you are the key to safety. Good safety practices not only protect you but also the people around you. Make 

these practices a working part of your safety program. Be certain that everyone operating in or around a confined space 

is familiar with the procedures recommended and follows safety precautions. Remember, most accidents can be pre-

vented. Do not risk injury or death by ignoring good safety practices.

• 

The most important safety device on this equipment is a safe operator. It is the operator’s responsibility to read 

and understand all safety and operating instructions in the manual and to follow these. Most accidents can be 

avoided.

• 

A person must understand the operation of this equipment and be trained in it’s usage before operating the 

equipment.  An untrained operator exposes himself and others to possible serious  injury or death.

• 

Do not modify the equipment in any way. Unauthorized modification may impair the function and/or safety and 

could affect the life of the equipment.

• 

Think SAFETY! Work SAFELY! 

4.0 - Safety

4.1 - Safety Alert Symbol

SAFETY ALERT SYMBOL

This Safety Alert symbol means 

AtteNtION! BeCOMe Alert! yOur SAFety 

IS INVOlVeD!

The Safety Alert symbol identifies important safety messages on your Pelsue Con-

fined Space Product and in the manual. When you see this symbol, be alert to the 

possibility of personal injury or death. Follow the instruction in the safety message.

Why is this symbol important to you?

3 BIG Reasons: 

Accidents Disable and Kill.

 

Accidents Cost You Money.

 

Accidents Can Be Avoided.

!

Summary of Contents for 115057-001

Page 1: ...nual Model 1400P Axial Ventilator 12VDC T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Tel 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ISO 9001 Certified ...

Page 2: ... 115057 001 Product Manual Model 1400P Axial Ventilator Revision 07 Date 03 28 2014 Page 2 ...

Page 3: ...tinuing reputation for excellence in the production of fine products for a broad spectrum of industry throughout the world Now in our second generation of family direction continued commitment to innovation and quality makes Pelsue a leading source of equipment for many types of confined spaces We specialize in safety retrieval fall arrest ventilation cable placing splicing and maintenance nationa...

Page 4: ...eneral Information 5 1 1 Quality Policy 1 2 Pelsue Product Warranty 2 0 Introduction Product Information 7 2 1 Serial Number 3 0 Configuration Assembly 8 3 1 Parts Diagram List 4 0 Safety 10 4 1 Safety Alert Symbol 4 2 General Safety Information 5 0 Product Operation 12 5 1 Product Description Capabilities 5 2 Start Up Operating Procedures ...

Page 5: ...tisfaction is one of the differentiators that sets you apart from the pack and yields a competitive advantage Therefore we will support total customer satisfaction by implementing the ISO 9001 Quality System and providing the necessary atmosphere and training to nurture this concept throughout our organization We will make every business decisionas though the quality of the part or service provide...

Page 6: ...er shall be limited to the repair or replacement of the product or component as set forth above and shall not include any liability whatsoever for damages caused by such failure including but not limited to consequential or incidental dam ages flowing from use or lack of use of product Any replacement repair modification installation or other service performed by the T A Pelsue Company shall be wa...

Page 7: ...tenance and inspec tion instructions contained within this manual This manual covers the Pelsue Model 1400P Axial Ventilator Use the Table of Contents as a guide to find specific information Keep this manual handy for frequent reference and to pass on to new operators 2 1 Serial Number Product Serial Number Always give your dealer the serial number of your Pelsue confined space ventilator product ...

Page 8: ...A 3 8 SHAFT 3450 RPM ALUM CW 1 5 118809 001 MOTOR MOUNT AxIAL BLOWERS HDPE STEEL BLOWER HOUSINGS 1 6 100188 001 FOOT RUBBER 3 4 OD W WASHER 4 7 118284 001 SCREW MACHINE PAN HD PHILLIPS 10 32 x 5 8 STAINLESS 4 8 121861 001 SHAFT ExTENSION 1400 SERIES BLOWERS CARBON STEEL 1 9 104638 001 SCREW SET CUP POINT 8 32 x 3 8 GRADE 5 PLATED 1 10 122592 001 PLUG BATTERY CLIP ASSEMBLY 12 VDC 30 AMP 1 11 110000...

Page 9: ...t Manual Model 1400P Axial Ventilator Revision 07 Date 03 28 2014 Page 9 3 1 Parts Diagram List continued Figure 3 1a 1400P Parts Diagram A 17 14 4 5 19 15 19 12 18 8 13 3 22 6 7 21 12 10 15 16 11 20 16 15 DETAIL A 9 14 ...

Page 10: ...ies of the 1400P Axial Ventilator and alert you to all good safety and operating practices while using the system Remember you are the key to safety Good safety practices not only protect you but also the people around you Make these practices a working part of your safety program Be certain that everyone operating in or around a confined space is familiar with the procedures recommended and follo...

Page 11: ... other than its intended use 2 Do not wear loose clothing that can become entangled in operating machinery Do not operate the ventilator without inlet or outlet screen guards in place If guards are missing or damaged contact the factory for replacements 3 Do not place fingers or any other object through inlet or outlet screens 4 Always operate the ventilator from a properly wired configured 12VDC ...

Page 12: ...minimum in rush rating amperage of 50 amps and a continuous duty of 15 to 18 amps Many automotive power ports cigarette lighter outlets are not rated for the required 15 amp draw the T A Pelsue Company is not liable for any damage incurred when connecting the ventilator to an under rated 12VDC power supply source Axial Ventilator 1400P General Specifications Weight 12 LBS 5 5 Kg Height 15 Width 13...

Page 13: ... as a guide to determine whether the equipment is in good operating condition prior to usage Equipment that is not in good condition can endanger the safety of the entrant and attendant during use The Pre Operation Visual Inspection is not limited to but must include the following items a Check the ventilator inlet and outlet guard screens for obstructions b Remove any objects around the immediate...

Page 14: ...d around the molded legs Important Notes During confined space entry operations it should not be assumed that the ventilator will maintain the air inside the confined space at a safe condition When the ventilator is in use the air inside the confined space should be monitored continuously for the presence of poisonous gases and or toxic fumes Ensure that the ventilator provides positive airflow th...

Page 15: ......

Page 16: ...ISO 9001 Certified T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Toll free 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ...

Reviews: