PelPro Cast Pellet Stove • 7093-600 • 07/13/16
pelprostoves.com
9
Installing
Your
Stove
Installing Your Stove
Confirm required clearances to combustibles:
Notice:
Be careful to protect the bottom of the stove
and floor surfaces when moving the stove. Bottom
edges of stove are sharp and can scratch surfaces.
1
1
2
3
Vertical Installations (Interior Flue)
Straight back against wall
Inches
mm
D
Back wall to pellet pipe
3
76
E
Side wall to stove
13
330
USA Hearth Pad Requirements
Inches
mm
A
Sides
2
51
B
Back
2
51
C
Front
6
152
Horizontal Installations
Straight back against wall
Inches
mm
G
Back wall to stove
2
51
E
Side wall to stove
13
330
H
Clearance to top of stove
7
178
J
Clearance to front of stove
48
1219
Corner Installation
Straight back against wall
Inches
mm
F
Walls to stove
3
76
2
B*
A
C
A
Placing Your Stove
Stove must be installed on a non-combustible floor.
If needed, place floor protection (such as a hearth
pad) beneath the stove. Move stove from pallet onto
your non-combustible surface. Do not operate the
stove while it sits on the pallet.
Hearth pad minimum requirements:
Notice:
Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction.
Non-combustible floor protection extending beneath the flue pipe is required
with horizontal venting or under the top vent adapter with vertical installation.
*Non-combustible floor protection must extend 2 inches (51mm) beneath the
flue pipe when installed horizontal venting or under the top vent adapter with
vertical installation. CANADA REQUIRED, USA RECOMMENDED.
3
G
E
D
J
F
F
J
H
J
Canada Hearth Pad Requirements
Inches
mm
A
Sides
8
203
B
Back
2
51
C
Front
6
152