DK9802C2 PV50c user manual ENG
Vers: C2 page8/38
Figure 1 Typical setup
Figure 2 Main installation components
4.1
Principal function
The PV50c burner is meant to be installed in a boiler and fuelled with wood pellets. The burner starts
always the operation by running a self test to ensure everything is working correctly. The burner is
equipped with a controller which is responsible monitoring and regulating all the processes of the
burner. Then a command is given to external auger which transports the pellets from a pellet storage
unit to the burner and from burner into the combustion chamber. After the delivery of fuel, the igniter
ignites the pellets. The air necessary for the combustion of the fuel is supplied by fan. Ash from
combustion in the burning chamber will be cleaned periodically by moving grates.
The burner will start and stop itself automatically according to the requirement of the heat. The burner is
equipped with several security features that protect it against overheating and that deal with other risks
that may arise during the operation.
The burner starts burning when the boiler temperature cools down and boilers thermostat switches on.
Burner runs until the pre-set maximum boiler’s temperature (switch-off temperature) has been reached.
After that burner stops safely burning procedure and goes to waiting status.
1
3
4
5
2
1.
Container
2.
Melting hose
3.
External auger
4.
Boiler
5.
Burner
On
are
depicted
main
components for installation:
1.
Case of burner
2.
Flange fixating M8 screws 4 pcs*
3.
Flange
4.
Ceramic seal
5.
Burning chamber
6.
Washers M8 4 pcs*
7.
Boiler’s door
*Not in set