A. 

Apply side flashing tape.

 Cut two pieces of flashing tape 4" 

longer than the frame height of the door. Apply one piece 1/2" 
onto the frame cladding, over the nailing fin and onto the water 
resistive barrier on each side. The tape should extend 2" above the 
top of the door and 2" below the bottom of the door. Press the 
tape down firmly while folding down the excess tape at the top 
and bottom of the door. 

Interior

Exterior

Fixed Panel

Threshold

3H

3G

Architect Series and Designer Series

3

 SETTING AND FASTENING THE DOOR (CONTINUED)

Exterior

4A

1"

4B

G.

 Architect Series and Designer Series:

 Apply sealant and insert a #8 x 2-1/2" pan head screw 

(provided) into each hole in the bottom of the door frame (shown above in gold). Another 
option is to use 3/16’ x 1-3/4” concrete screws. Drill pilot holes per manufacturers instructions.

Note: The flashing tape must be applied approximately 1/2" onto 
the frame cladding at the jambs and head. Pre-folding the tape 
at 1/2" before removing the paper backing will make it easier to 
apply the tape correctly. If the siding is less than 1/2" thick, adjust 
the dimension of the fold so the exterior sealant line will cover the 
exterior edge of the tape.

B. 

Apply top flashing tape.

 Cut a piece of flashing tape long 

enough to go across the top of the door and extend at least 1" 
past the side flashing tape on both sides. Apply the tape 1/2" 
onto the frame cladding, over the top nailing fin as shown. Fold 
the overlapping tape down, and press all tape down firmly.

Note: The top flashing tape must overlap the side flashing tape 
to prevent water from getting behind it.

H.

 Architect Series and Designer Series:

 Position and secure the panel retainer by drilling pilot 

holes through the remaining holes in the retainer into the sill support or wood blocking, then 
apply sealant to the holes and insert a screw into each hole as specified below.

 

Aluminum sill support:

 9/64" pilot holes, #10 x 3/4" flat head thread cutting screws 

(provided).

 Wood 

blocking:

 1/8" pilot holes, #10 x 2-1/2" flat head wood screws (provided). 

 Masonry 

floor:

 3/16” x 1-3/4” concrete screw. Pilot drill per screw manufacturer’s 

recommendations.

I. 

Remove the factory installed screws

 from the retainer and repeat the process.

J.

  Architect Series and Designer Series:

 Drill a 

3/16" clearance hole at each indentation in the 
extrusion at the top (head) of the door frame 
into the rough opening, stopping when the drill 
is through the door frame.  Apply sealant to 
each hole, then insert a #8 x 3" pan head screw 
into each hole.

6HDODQW

JRHV

KHUH

´

3J

Summary of Contents for 801W0103

Page 1: ...t may require an installation method different from these instructions and additional care Determining the appropriate installation method is the responsibility of you your architect or construction p...

Page 2: ...ammer Stapler Scissors or utility knife Screwdrivers 2 Phillips with 8 shaft and small flat blade Drill Sealant gun SEALANT SEALANT REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT 1ROUGH OPE...

Page 3: ...the opening width Apply at the bottom overlapping tape 1 by at least 1 Do not allow the tape to extend past the interior face of the framing 1G Note The flashing tape may not fully cover the framing...

Page 4: ...allow equal clearance for shimming and insert one roofing nail in the first hole from the corner on each end of the top nailing fin These are used to hold the door in place while shimming it plumb an...

Page 5: ...nt line will cover the exterior edge of the tape B Apply top flashing tape Cut a piece of flashing tape long enough to go across the top of the door and extend at least 1 past the side flashing tape o...

Page 6: ...ater resistive barrier at both upper corners of the door Note Be sure to overlap the top corners 4D B Install the handles and panel retainer Follow the instructions included in the hardware box If the...

Page 7: ...side of Accessory Groove Accessory Groove Sealant typical 3 8 3 8 BRICK VENEER 3 8 Clearance Backer Rod and Sealant typical Perimeter Sealant must extend to room side of Accessory Groove Accessory Gro...

Page 8: ...ompletely before closing them Pella Corporation is not responsible for interior paint and stain finish imperfections for any product that is not factory applied by Pella Corporation Use of inappropria...

Reviews: