.11
PELICAN
PRO-RO 6 Instruction Manual
Feed and Drain Connection
1. Locate and turn off the angle stop valve on the cold water line feeding the sink.
This valve will usually be located under the sink on the pipe coming out of the wall.
2. When the angle stop valve is closed, relieve pressure in the line by momentarily
opening the cold water tap on the sink.
3. Disconnect the cold water faucet feed line at the angle stop valve.
4. Install the feed valve assembly into the angle stop. (Fig. 1)
5. Firmly press the green 1/4
〃
tubing into the 1/4
〃
connector on the feed valve assembly.
6. Connect the cold water faucet feed line into the feed valve assembly.
7. Make sure the small shut-off valve on the feed valve assembly is closed. Turn on
the feed water connection valve. Check for leaks.
8. Attach the small feed valve warning tag from the parts bag to the feed valve.
9. Attach the Shutoff Warning label to the system so that it is directly visible. Fill out
the Date of Installation label and attach to the side of the system.
1. You will need an electric drill with a 3/8
〃
bit and a screwdriver for this portion of
the installation.
2. Obtain the drain saddle assembly, two 1 ½
〃
bolts, two 3/8
〃
hex nuts, and the
small adhesive foam pad from the small parts bag (Fig. 2).
3. Place the adhesive foam pad on the inside of the the drain saddle front, aligning
the holes.
4. Position the drain saddle on the drain pipe under the sink between the
“
P
”
trap
and the sink connection. Orient the drain saddle so that the opening is on the
side of the drain pipe.
5. Using the bolts and hex nuts, hand tighten the saddle bracket evenly until the
saddle grips the pipe snugly. Use a Phillips screwdriver to fully tighten the bolts.
Do not overtighten.
6. If necessary, remove the drain saddle connector nut from the opening of the
drain saddle. Using the connector opening in the side of the drain saddle as a
guide, drill a 3/8" hole through the wall of the drain pipe.
7. Extend the drain tubing from the RO dispensing faucet to the drain saddle and
measure for length. The tubing must be routed so that water can run downhill for
the entire length of the tubing from the faucet. Avoid low spots or loops. Cut the
tubing shorter, if necessary.
8. Insert the drain tube from the R.O. dispensing faucet through the drain saddle
connector nut. Tighten the connector nut onto the drain saddle.
Feed Connection
Drain Connection
Fig. 2
Fig. 1
The drain saddle assembly must be
installed before the 'P' trap. Do not
install the drain saddle assembly
between the 'P' trap and the wall.
The feed valve adapter may be
configured to fit either a 3/8" or 1/2"
angle stop connection by changing
the location of the adapter.
NOTE
NOTE
Shut-off valve
Angle stop
Adapter
Summary of Contents for PRO-RO6
Page 1: ......
Page 2: ...Brand Story Pelican 2007...
Page 3: ......
Page 16: ...15 PRO RO 6 30 1 2 3 4 5 1 RGA 2 3 4 2 7bar 4 38 RO...
Page 17: ...16 PRO RO 6 6 12 85 1 4 4 1 20 2 GAC 3 4 18 104863 5 6 GAC 6 12 104851...
Page 19: ...18 PRO RO 6 AS 15 30 www epa gov safewater arse nic html AS V As 5 AS III As 3 RO 300 10...
Page 21: ...20 PRO RO 6 1 4 3 8 2 1 1 1 1 4 2 2 3 4 5 6 7 8 3 8 3 8 2 9 1 4 1 4 10 11 3 8 3 8 2 3...
Page 22: ...21 PRO RO 6 1 2 3 4 1 5 1 4 1 4 6 7 8 9 1 3 8 2 1 1 2 3 8 2 3 4 P 5 6 3 8 7 8 1 1 P P 3 8 1 2...
Page 23: ...22 PRO RO 6 1 2 3 5 4 15 5 6 1 2 8 3 8 4...
Page 24: ...23 PRO RO 6 1 2 3 4 5 6 7 8 9 10 8 1 2 40 80 3 4 5 6 7 2 8...