Product Operation and Specifications
Important Information
Read these instructions carefully and determine the location of all system components before
beginning installation.
Check all applicable plumbing, building, and electrical codes for installation compliance.
Install the system on the main water supply.
Systems that contain electronic components cannot be installed outside in uncovered areas.
!IMPORTANT!
Your system will not be ready for use for a minimum of 48 hours while the Carbon Soak process takes
place. Please plan your install accordingly.
WARNING:
If this or any other system is installed in a metal (conductive) plumbing system, i.e. copper or
galvanized metal, the plastic components of the system will interrupt the continuity of the
plumbing system. As a result any errant electricity from improperly grounded appliances
downstream or potential galvanic activity in the plumbing system can no longer ground
through contiguous metal plumbing. Some homes may have been built in accordance with
building codes, which actually encouraged the grounding of electrical appliances through the
plumbing system. Consequently, the installation of a bypass consisting of the same material
as the existing plumbing, or a grounded "jumper wire" bridging the equipment and re-
establishing the contiguous conductive nature of the plumbing system must be installed prior
to your systems use.
CAUTION:
When adding a filtration/softening system to homes/buildings supplied by well water, the system should be
installed following the pressure tank. DO NOT USE this system for pneumatic or hydro pneumatic
applications. If you are using a booster pump, then install this system following the booster
pump. If you have questions, please call customer service.
Specification Description
1865
2162
Rated Service Flow
30 GPM
35 GPM
Minimum Working Pressure
25 PSI
Maximum Working Pressure
80 PSI
Maximum Vacuum
5 inch/127 mm Hg
Operating Temperatures
36°F - 120°F
pH Range
6 - 11
Pelican
Water
Systems