Operating instructions
•
This tool applies to operate on clean, dry and
compressed air at regulated pressure at 2.0 bar.
Too low or too high pressure is not allowed.
•
Check and replace any damaged or worn parts
on the tool, make sure the trigger and nozzle can
operate well.
•
Connect the gun to the air supply, fluid cap, con
-
tainer and air hose should be connected tightly
with the spray gun.
•
When painting, grip the gun keeping perpendi-
cular with the spraying area then move it paral-
lel several times, the trigger should be locked
before the stroke ends. Keep the appropriate
distance of 6-8 inches between the gun and ray-
ing area, according to the atomization pressure
and work demand. Just like fig 5 shows.
Adjustment
The desired pattern, volume of fluid output and fine
atomization can easily be obtained by regulating the
pattern adjusting knob, fluid adjusting knob and air
adjusting knob.
Adjusting pattern:
Turning Pattern Adjusting the Knob to the right until
tight will make the spray pattern round, or turning it
left, will make the spray pattern ellipse
Adjusting volume of fluid output:
Turn the fluid adjusting knob, clockwise will reduce
the volume of fluid output and counter-clockwise
will increase fluid output.
Adjusting air volume:
Turning the Air Adjusting valve clockwise will reduce
the air volume. And counter-clockwise will increase
the air volume.
Maintenance
Pour remaining paint into another container and
then clean paint passage and air cap. Spray a small
amount of thinner to clean the passage. Incomplete
cleaning will cause adverse pattern sharpness and
particles. Clean other sections with an attached
brush, soaked with thinner.
Caution
Never use the wire or other hard things to dig the
nozzle, fluid needle , this will cause damage to them.
Never immerse spray gun completely in thinner or
solvent. When reassembly, always clean parts to
prevent the sticking of dust.
ENGLISH