Maintenance
NOTE
: Disconnect power and air before
maintenance. Change the solvent if necessary.
Cleaning
: Clean the solvent filter (7) regularly to
avoid clogging.
Changing the solvent
: Use the water outlet to get
dirty solvent out of the tank. Turn the φ12 water
drain tap and unscrew the fixed bolt to remove the
tank for cleaning.
Wiring diagram
Troubleshooting
Problem
Possible cause
Measure
Cleaning gun only works
with air and no longer with
solvent.
1. The clean button is OFF
2. Insufficient solvent
3. The absorption tube is
blocked
1. Turn it on.
2. Add more solvent to the
tank.
3. Check and clean the ab
-
sorption tube.
The light does not work
but the fan still works.
1. The light is broken.
1. Replace with a new one.
The fan does not work but
the light still works.
1. The fan is broken.
1. Pull out the waterproof plug
and replace with a new fan.
The temperature control
display is abnormal.
1. Flight plug is not
connected properly.
1. Double check the
connection.
The temperature cannot
reach what you set it to.
1. Insufficient solvent.
2. Heating on / off the switch
is off.
3. The heating pipe is broken.
1. Add more solvent
2. Turn on the power switch
3. Replace with a new heating
pipe