5.5 DC input mode in parallel for three phase inverters
For the connection of only one DC line on 2 inputs, compatibly with electrical
features, it is recommended the configuration of inputs in parallel. For this
connection mode it is suggested to use Y-wires as in diagram. There are no
display settings available for parallel connection of strings.
5.6 Connection to communication and monitoring interface
The Virtus inverters are equipped with an RS-232 interface and an RS-485 interface
1. VCC
2. TxD (Transmit external data)
3. RXD (Receive external data)
4. NC
5. GND (Signal Ground)
6. NC
7. NC
8. NC
9. VCC
6
5
7
4
8
3
9
2 1