452-FUEPMF-Rev02_061002.pdf
GB - 1
Paul Hochköpper GmbH & Co. KG • Postfach 1727 • D-58467 Lüdenscheid • Tel.: (02351)185-0 • Fax: (02351)27666 • e-mail: [email protected] • Internet: www.peha.de
126312-01
1. Description
Different consumers can be switched potential-free with the
output 1
L
(channel 1) and output 2
L
(channel 2) of the receiver.
The Easyclick switching receiver is controlled by radio signals
from Easyclick transmitters. Each transmitter can simultan-
eously control an unlimited number of receivers.
The transmitters have a fixed address and must be assigned
on a receiver (max. 32 transmitters).
The memory of each receiver is empty when delivered.
Function 1
(two-button function) is preset by default in the
receiver of a freshly assigned transmitter.
The receiver’s function can be changed by programming
to respond to any assigned transmitter (see Point 6).
2. Mounting
Hand-held
2-channel transm.:
4-channel transm.:
transmitter:
- 95.450.xx FU-BLS
- 95.455.xx FU-BLS
- 450 FU HS4
- 20.450.xx FU BLS
- 20.455.xx FU BLS
- 20.450.xx FU BLS N
- 20.455.xx FU BLS N
- 450 FU-BLS
- 455 FU-BLS
Mounting and set-up may only be carried out by an authorised
professional.
All works may only be performed once the mains power supply
24V DC has been switched off. Mounting must adhere to the
valid laws, standards and regulations.
For programming, the receivers must be connected to the
mains power supply. The programming is retained even in a
power failure.
NEVER mount the Easyclick transmitter or receiver in a metal
housing or directly next to large metal objects.
It is also not advisable to mount the receivers on the floor or
close to the floor.
The following points must be observed:
- the valid laws, standards and regulations
- the best available technology at the time of installation.
- the operating instructions of the Easyclick-modules.
- the fact that operating instructions can only contain general
guidelines and that these must be considered in the context
of a specific system.
Caution!!
The Easyclick-modules must
not
be used with
devices, which could affect human health or safety, or en-
danger humans, animals or material assets.
3. Technical data
Installation and operating instructions
Multifunction switching receiver
for Easyclick transmitters
Art.no.:
452/24 FU-EP-MF o.T.
GB
s.
Point
4
5. Deleting all assigned transmitters
Press the
CLR/MODE
button
and hold it down for approx. 2s.
During this time, the memory is completely deleted (delivery
status). Then, the receiver is in learn mode (LED 1 flashes red).
Press the
CLR/MODE
button for longer
All assigned
transmitters deleted
Learn mode
channel 1
(LED 1 flashes red)
6. Function programming
The Easyclick receiver’s
function
and its
parameter
can
be changed by function programming each
assigned
Easyclick transmitter (see Point 4).
Function programming is activated by pressing an holding the
LRN/SET
button until confirmed (LEDs flash green rapidly).
Function programming can be manually terminated by
activating the
CLR/MODE
button.
Without activating the button on a transmitter, the receiver will
terminate function programming automatically after about 30s.
If function programming is active, a button of the transmitter
must be pressed for recognition, for which the function of
the receiver is to be changed.
Once the transmitter is recognized by the receiver, the receiver’s
active channel will be the one on which the transmitter was
assigned (LED 1 or LED 2 flashes orange).
The number of times the LED flashes corresponds to the
receiver’s current function. This function can then be changed
by the number of times that the
LRN/SET
button is activated
(e.g. pressing
LRN/SET twice
= Function 2).
The parameter setting is accessed in function programming
by activating the
CLR/MODE
button.
Afterwards the channel is active, on which the transmitter
was assigned (LED 1 or LED 2 flashes green).
Parameter setting can be manually terminated by activating
the
CLR/MODE
button.
The number of times the LED flashes corresponds to the
parameter currently set for the receiver’s current function.
This parameter can then be changed by the number of times
that the
LRN/SET
button is activated
(e.g. pressing
LRN/SET twice
= Parameter 2).
Caution!!
If an Easyclick
transmitter has been assigned
on both channels, the functions and parameters of both
channels of the Easyclick receiver can be changed!
If channel 1 is initially active (LED 1 flashes) for function
programming then the function and parameter for channel
1 can be changed.
When the
CLR/MODE
button is subsequently pressed,
channel 2 will become active (LED 2 flashes) for function
programming so that the function and parameter for channel
2 can also be changed.
Recognition of transmitter
Press a button of the transmitter
Idle state
(LED off)
Press the
CLR/MODE
button briefly
Press the
LRN/SET
button for longer
Function programming
(LEDs flash green rapidly)
Channel 1 or 2 is active
(LED flashes orange)
number of flashing = function
Press the
LRN/SET
button to
select the function 1-8
number of actuations = function
Press the
CLR/MODE
button briefly
Parameter setting
Channel 1 or 2 is active
(LED flashes green)
number of flashing = parameter
Press the
LRN/SET
button to
select the parameter
number of actuations = function
9 m
m
24VDC
COM
2
1
max.2x300mA
1
2
COM
no
no
+
—
24V DC
extern
+
-
GND
CLR/MODE-button
Parameter setting
LRN/SET-button
Learn mode and
Function
programming
Learn mode:
LED = red
Function programming:
LED = green oder orange
1
com 2
Internal circuit diagram
Assign/delete transmitter
Press a button of the
transmitter
once
2x
Transmitter assigned
(LED 1-2 on)
Receiver function 1
Transmitter deleted
(LED 1-2 off)
4. Assigning or deleting Easyclick transmitters
Easyclick transmitters can be assigned or deleted in the
learn
mode
of the receiver.
Learn mode is activated by pressing the
LRN/SET button
and the channel 1 is active (LED 1 flashes red).
If the
LRN/SET
button is pressed a second time, channel 2
becomes active (LED 2 flashes red).
An Easyclick transmitter can be assigned on both channels!
If a button of the transmitter that
is to be assigned
is pressed
once
in learn mode and recognized by the receiver (
LED on
),
the transmitter
has been assigned
.
To delete a assigned transmitter, the channel on which it was
assigned must be selected!
If a transmitter has been assigned on both channels, then it
must also be deleted on both channels (if this is desired)!
If a button of an
already assigned
transmitter is pressed
once
and recognized (
LED off
), the transmitter
has been deleted
.
Caution!!
If the button off a transmitter is pressed repeatedly
the transmitter will be alternately assigned or deleted!
After an Easyclick transmitter has been assigned or deleted
the receiver returns to learn mode for channel 1 or channel 2
and other transmitters can be assigned or deleted.
When no button of an Easyclick transmitter is pressed, the
receiver leaves the learn mode after approx. 30s independently.
Press the
LRN/SET
button briefly
Learn mode
channel 1-2
(LED 1-2 flashes red)
Press the
LRN/SET
button briefly
Learn mode OFF
(LED off)
Function 1
(two-button function) is preset by default in the
receiver of a freshly assigned transmitter.
If desired, the receiver’s function and its parameter can be
changed by function programming (see Point 6) for each
assigned
transmitter.
Transmission frequency
868.3 MHz
Power supply
24V DC
Capacity per output
Max. 300mA (24V DC)
Ambient temperature
-20° to +40
q
C
Storage temperature
-40° to +85°C
Test specifications
EN 60669-2-1
Certifications
CE
Protection level
IP 20