background image

452-FUEPMF-Rev02_061002.pdf

GB - 1

Paul Hochköpper GmbH & Co. KG • Postfach 1727 • D-58467 Lüdenscheid • Tel.: (02351)185-0 • Fax: (02351)27666 • e-mail: [email protected] • Internet: www.peha.de

126312-01

1. Description

Different consumers can be switched potential-free with the
output 1

L

 (channel 1) and output  2

L

 (channel 2) of the receiver.

The Easyclick switching receiver is controlled by radio signals
from Easyclick transmitters. Each transmitter can simultan-
eously control an unlimited number of receivers.
The transmitters have a fixed address and must be assigned
on a receiver (max. 32 transmitters).
The memory of each receiver is empty when delivered.

Function 1

 (two-button function) is preset by default in the

receiver of a freshly assigned transmitter.
The receiver’s function can be changed by programming
to respond to any assigned transmitter (see Point 6).

2. Mounting

Hand-held

2-channel transm.:

4-channel transm.:

transmitter:

- 95.450.xx FU-BLS

- 95.455.xx FU-BLS

- 450 FU HS4

- 20.450.xx FU BLS

- 20.455.xx FU BLS

- 20.450.xx FU BLS N

- 20.455.xx FU BLS N

- 450 FU-BLS

- 455 FU-BLS

Mounting and set-up may only be carried out by an authorised
professional.
All works may only be performed once the mains power supply
24V DC has been switched off. Mounting must adhere to the
valid laws, standards and regulations.

For programming, the receivers must be connected to the
mains power supply. The programming is retained even in a
power failure.

NEVER mount the Easyclick transmitter or receiver in a metal
housing or directly next to large metal objects.
It is also not advisable to mount the receivers on the floor or
close to the floor.

The following points must be observed:

- the valid laws, standards and regulations
- the best available technology at the time of installation.
- the operating instructions of the Easyclick-modules.
- the fact that operating instructions can only contain general

guidelines and that these must be considered in the context
of a specific system.

Caution!!

 The Easyclick-modules must 

not

 be used with

devices, which could affect human health or safety, or en-
danger humans, animals or material assets.

3. Technical data

Installation and operating instructions

Multifunction switching receiver
for Easyclick transmitters

Art.no.: 

452/24 FU-EP-MF o.T.

GB

s. 

Point 

4

5. Deleting all assigned transmitters

Press the 

CLR/MODE

 

button

 and hold it down for approx. 2s.

During this time, the memory is completely deleted (delivery
status). Then, the receiver is in learn mode (LED 1 flashes red).

Press the 

CLR/MODE

button for longer

All assigned
transmitters deleted

Learn mode

 

channel 1

(LED 1 flashes red)

6. Function programming

The Easyclick receiver’s 

function 

and its 

parameter 

can

be changed by function programming each 

assigned

Easyclick transmitter (see Point 4).

Function programming is activated by pressing an holding the

LRN/SET

 button until confirmed (LEDs flash green rapidly).

Function programming can be manually terminated by
activating the 

CLR/MODE

 button.

Without activating the button on a transmitter, the receiver will
terminate function programming automatically after about 30s.

If function programming is active, a button of the transmitter
must be pressed for recognition, for which the function of
the receiver is to be changed.
Once the transmitter is recognized by the receiver, the receiver’s
active channel will be the one on which the transmitter was
assigned (LED 1 or LED 2 flashes orange).
The number of times the LED flashes corresponds to the
receiver’s current function. This function can then be changed
by the number of times that the 

LRN/SET

 button is activated

(e.g. pressing 

LRN/SET twice

 = Function 2).

The parameter setting is accessed in function programming
by activating the 

CLR/MODE

 button.

Afterwards the channel is active, on which the transmitter
was assigned (LED 1 or LED 2 flashes green).
Parameter setting can be manually terminated by activating
the 

CLR/MODE

 button.

The number of times the LED flashes corresponds to the
parameter currently set for the receiver’s current function.
This parameter can then be changed by the number of times
that the 

LRN/SET

 button is activated

(e.g. pressing 

LRN/SET twice

 = Parameter 2).

Caution!!

 If an Easyclick 

 

transmitter has been assigned

on both channels, the functions and parameters of both
channels of the Easyclick receiver can be changed!
If channel 1 is initially active (LED 1 flashes) for function
programming then the function and parameter for channel
1 can be changed.
When the 

CLR/MODE

 button is subsequently pressed,

channel 2 will become active (LED 2 flashes) for function
programming so that the function and parameter for channel
2 can also be changed.

Recognition of transmitter

Press a button of the transmitter

Idle state

(LED off)

Press the 

CLR/MODE

button briefly

Press the 

LRN/SET

button for longer

Function programming

(LEDs flash green rapidly)

Channel 1 or 2 is active

(LED flashes orange)
number of flashing = function

Press the 

LRN/SET

 button to

select the function 1-8

number of actuations = function

Press the 

CLR/MODE

button briefly

Parameter setting

Channel 1 or 2 is active

(LED flashes green)
number of flashing = parameter

Press the 

LRN/SET

 button to

select the parameter

number of actuations = function

9 m

m

24VDC

COM

2

1

max.2x300mA

1

2

COM

no

no

+

24V DC 
extern

+

-

GND

CLR/MODE-button
Parameter setting

LRN/SET-button
Learn mode and

Function
programming

Learn mode:
LED = red

Function programming:

LED = green oder orange

1

  com   2

Internal circuit diagram

Assign/delete transmitter

Press a button of the
transmitter 

once

2x

Transmitter assigned

(LED 1-2 on)

Receiver function 1

Transmitter deleted

(LED 1-2 off)

4. Assigning or deleting Easyclick transmitters

Easyclick transmitters can be assigned or deleted in the 

learn

mode

 of the receiver.

Learn mode is activated by pressing the 

LRN/SET button

and the channel 1 is active (LED 1 flashes red).
If the 

LRN/SET

 button is pressed a second time, channel 2

becomes active (LED 2 flashes red).

An Easyclick transmitter can be assigned on both channels!
If a button of the transmitter that 

is to be assigned

 is pressed

once

 in learn mode and recognized by the receiver (

LED on

),

the transmitter 

has been assigned

.

To delete a assigned transmitter, the channel on which it was
assigned must be selected!
If a transmitter has been assigned on both channels, then it
must also be deleted on both channels (if this is desired)!
If a button of an 

already assigned

 transmitter is pressed 

once

and recognized (

LED off

), the transmitter 

has been deleted

.

Caution!!

 

If the button off a transmitter is pressed repeatedly

the transmitter will be alternately assigned or deleted!

After an Easyclick transmitter has been assigned or deleted
the receiver returns to learn mode for channel 1 or channel 2
and other transmitters can be assigned or deleted.
When no button of an Easyclick transmitter is pressed, the
receiver leaves the learn mode after approx. 30s independently.

Press the 

LRN/SET

button briefly

Learn mode

 

channel 1-2

(LED 1-2 flashes red)

Press the 

LRN/SET

button briefly

Learn mode OFF

(LED off)

Function 1

 (two-button function) is preset by default in the

receiver of a freshly assigned transmitter.
If desired, the receiver’s function and its parameter can be
changed by function programming (see Point 6) for each

assigned 

transmitter.

Transmission frequency

 

868.3 MHz

 

Power supply

 

24V DC

 

Capacity per output 

Max. 300mA (24V DC)

 

Ambient temperature

 

-20° to +40

q

C

 

Storage temperature

 

-40° to +85°C

 

Test specifications

 

EN 60669-2-1

 

Certifications

 

CE

 

Protection level

 

IP 20

 