PEHA Elektro GmbH & Co. KG

Postfach 1727 • D-58467 Lüdenscheid • Tel.: (02351)185-0 • Fax: (02351)27666 • e-mail: [email protected] • Internet: www.peha.de

 

coDIng swITch

The output module‘s address is set by the coding switch built into the PHC control 

module. The setting of the coding switch is presented in the PHC software under the 

menu item „

Components 

g

 Edit Modules

“. 

Make sure that no identical module addresses are given for PHC output modules.

The setting of the coding switch may be carried out by technicians only. For this the 

PHC module needs to be switched off and it must be ensured that there can be no 

electrical discharge.

currenT consumPTIon

To calculate the current consumption for the power supply, you should assume a 

consumption of 60 mA (internal consumption 10 mA, per relay 6 mA). When a relay 

is switched on the current increases to 120 mA for about 2 seconds.

TechnIcaL DaTa

Power supply 

Phc system (Phc bus)

Nom. 24 V DC

21-28 V  DC (ripple voltage 5 %)

own consumption

10-60 mA

In-/output module bus

2 modular sockets 6-pin (PHC bus)

external voltage

(Terminal  I0+, I0-, I1+, I1-)

4 terminal clamps for the connection of 2 external 

power supplys (12-24V DC)

relay outputs 

(Terminal O0-O3)

8 outputs (O0-O3) in 4 groups with 2 terminals

clamps (+ and -) for loads up to 1 A (12-24V DC)

Life-time cycle of relays

50,000 switchings with max. load

coding

DIP switch, 5-pin (Module address)

ambient temperature

+10° to +50°C

storage temperature

-20° to +60°C

screw terminals

max. 2 x 1,5  mm²

Test specifications

EN 60669-2-1

approbationen

CE   KEMA/KEUR   CEBEC

Protection level

IP20

Dimensions

width  =  72 mm

height  =  55 mm

PermITTeD LoaDs For The reLay ouTPuTs

Type of load connected

max. output load per output

Motor load

1 A

warranTy conDITIons

These operating instructions are an integral part of both the device and our terms of 

warranty. They must be handed over to the user. The technical design of the appliance 

is  subject  to  change  without  prior  notification. 

PEHA

 products are manufactured 

and quality-checked with the latest technology according to applicable national and 

international regulations. Nevertheless, if a product should exhibit a defect, 

PEHA

 

warrants to make remedy as follows (regardless of any claims against the dealer to 

which the end user may be entitled as a result of the sales transaction):

In the event of a justified and properly established claim, 

PEHA

 shall exercise its 

prerogative to either repair or replace the defective device. Further claims or liability 

for consequential damage are explicitly excluded. A justifiable deficiency is deemed to 

exist if the device exhibits a structural, manufacturing, or material defect that makes it 

unusable or substantially impairs its utility at the time it is turned over to the end user. 

The warranty does not apply to natural wear, improper usage, incorrect connection, 

device tampering or the effects of external influences. The warranty period is 24 months 

from the date of purchase by the end user from a dealer and ends not later than 36 

months after the device’s date of manufacture. German law shall be applicable for the 

settlement of warranty claims.

DIsPosaL oF The DevIce

Do not dispose of old devices in the household waste! The device must be 

disposed of in compliance with the laws and standards of the country in which it 

is operated! The device contains electrical components that must be disposed 

of as electronics waste. The enclosure is made from recyclable plastic.

DescrIPTIon

The PHC output module 940/24 JRM can control four blinds or roller shutters by 

the outputs 

(o0-o3)

. The module features within the PHC software four separate 

channels for time measurement that can be used independently from the blind/roller 

shutter functions as virtual outputs. One channel for time measurement is used for 

example under the point 

„sun sensor delay time measurement“

 in the roller shutters/

blinds group tools for clocking the sun delay.

The module is divided into 4 groups and features 2 inputs to connect 2 external power 

supplys 

(12-24V DC)

. The upper terminal clamps 

(

I

0+, 

I

0-) 

supplies the upper 2 output 

groups 

(o0-o1) 

with the applied power supply and the lower terminal clamps 

(

I

1+, 

I

1-) 

supplies the lower 2 output groups 

(o2-o3)

The module switches the external 

positive voltage to one of the motor connections used 

(o0+ to o3+)

 for raising or 

lowering of a blind or roller shutter. In idle state the motors are connected by the motor 

connections 

(o0- to o3-)

 with the earth (GND).

connecTIon DIagram

safety recommendation!

During a reset of the PHC system 

(e.g. after an interruption of the power 

supply) all relay outputs are in home 

position (idle state).

Since all motor connections 

(o0- to 

o3-)

 are connected to earth (GND) in 

idle state it needs to be ensured that 

the earth (GND) of the external power 

supply is connected to the terminal

clamps 

I

0-

 and 

I

1-

.

m

m

+          -

External 

Voltage

(12 - 24V DC)

externe 

spannung

(12 - 24v Dc)

m

m

+          -

External 

Voltage

(12 - 24V DC)

V1+ V1- V1+ V1-

V1+ V1-

V1+ V1-

V1+

V1-

O0+

O2+

O0-

O2-

O1+

O3+

O1-

O3-

0+

I

1+

I

0-

I

1-

I

V0+ V0- V0+ V0-

V0+ V0-

V0+ V0-

V0+

V0-

M0

M2

M3

M1

940/24 JRM

PHC System

1A/12-24V DC (I

N          

max 4x1A)

M

M

coding switch 

module address

mounTIng

The installation of the PHC modules may be carried out by authorised technicians only. 

During installation the system‘s electricity has to be switched off. The PHC module is 

designed for mounting on a 35mm top hat rail acc. EN 50022 in  in-/on-wall distribution 

housing. The devices can be mounted directly next to each other.

attention!!

 The PHC modules may 

not

 be employed in connection with devices that 

may endanger people, animals or property when operated.

The following points must be observed:

-  the valid laws, standards and regulations

-  the technical state of the art during installation

-  the PHC manual and the operating instructions of the PHC modules.

-  the fact that operating instructions can only cover general regulations and that

  these regulations must be considered in the context of the PHC system. 

The following systems may not be switched by Phc modules:

-  safety switches such as EMERGENCY OFF

-  emergency power supplies

-  fire alarm systems

-  emergency lighting systems

DaTa connecTIon

The connection between PHC control unit and other PHC modules is established by 

the PHC bus line and the modular connectors of the modules. The module connectors 

are switched parallel in the modules (except in the PHC power supply unit) and 

therefore freely selectable as in- or output. Thus the PHC module can be positioned 

anywhere in the data line.

A PHC bus line of 30 cm length is included with every PHC module. It is needed for 

connecting a neighbouring module or for connecting a module in the next distributor 

row. The modules are supplied with voltage by the bus line. Power needs to be 

switched off before disconnecting the bus line.

InsTaLLaTIon anD oPeraTIng InsTrucTIons
Phc output modul 940/24 Jrm for blinds and roller shutters

8 outputs (2x 4x 1 a) for 4 Dc motors from 12 to 24v

940/24 Jrm

gb