VISION 2PLT
Pag. 12
Rev. 02-18
USE AND MAINTENANCE MANUAL
DOWN / ENTER MANUAL DEFROST MENU
(if long pressed)
ROOM LIGHT
DISPLAY LCD
1.
Ambient temperature / parameters
2.
Value of ambient probe / defrost 1 probe / defrost 2 probe / current
day / parameter value / alarm code
3.
System status / time / time parameter values
Zone
Written
displayed
Fixed state
Flashing state
C1
Compressor 1
active
Compressor 1 waiting for C1 delay, will be the
next to ignite (progr. 2°lev.)
C2
Compressor 2
active
Compressor 2 waiting for C1 delay, will be the
next to ignite (progr. 2°lev.)
d1
Evaporator 1
defrosting
Evaporator 1 in dripping
d2
Evaporator 2
defrosting
Evaporator 2 in dripping
Current time
Hour : minute : second
Defrost time
Hour: minute : second
dEFr
Defrost menu active
Regulation probe index
(displayed in zone 1)
1 = ambient probe 1
2 = ambient probe 2
A = mean of ambient probes
CHAP. 5 - Data programming
5.3