Installation – using adaptors
1
Remove the valve head by
unscrewing the fixing ring.
2
Select the appropriate
adaptor for the
thermostatic valve and
attach to the valve body.
Note: you will need to
open the adaptor with a
screwdriver for it to fit
fully onto the body
3
Use the small bolt and
nut to secure the adaptor
to the body.
4
Place the i-temp head
onto the valve body.
5
Turn the fixing screw by
hand until tight. Note: Do
not use grips or other
tools which may damage
the fixing ring.
An example of installation
using adaptor AD1.
36