37
Questions concerning the card reader
#Symptom 01
: The reader can not read card and get access
A.1—To check whether the proximity card is encoded correctly. Either
correct project number or card type. .
A.2—To check whether the proximity card is legal.
A.3—To check if the personal ID is enrolled in the reader by function
F6 of card adding.
#Symptom 02
: The reader can read card but can not get access
A.1—To check if the reader is at 3300 mode (card with code),the reader
lit green LED at left and you do not key-in the PIN within the
keypad waiting time.
A.2—To check if the reader is at 830t mode (unauthorized repeat card
within t minutes), if yes, you should try to get access after t
minutes. If 830t isn’t the mode you want, then you may change it
to 8300 code.
#Symptom 03
: The reader can get access (LED displayed “good” or
LCD displayed “---O.K.---“, but the door was not
released.
A.1—To check if you correctly wire the electrical lock device with the
correct power supply.
A.2—If the devices are all correctly wired and the wire is well
conducted, then hear if the relay is clicked. If yes, then the relay
contacts may be damaged. If not click, then the relay driver in the
circuit board may be bad or damaged. Please contact with the
distributor for repair or replacement.
◎
Wrong message on LCD display:
C.ERR –Illegal card no. A.ERR –Anti-pass back error
Z. ERR –Time zone error P. ERR – Password error
Q. ERR –Project no. error V. ERR –Out of validity date
RPT.ER
*
–Unable to read card repeatedly during the set time by
parameter code 830t
#Symptom 04:
The door was released but the duration is very short
A.1—If the door released period is not so long as you set by 21tt,then
please check if the door monitoring mode (1100/1)is set as 1101
Simple and easly trouble shooting