REPAIR PARTS

 9. REPAIR PARTS

Figure 9.1: Repair Parts

Repair parts are available from your local PB Heat, LLC distributor or from Parts To Your 

Door at 1 (610) 916-5380 (www.partstoyourdoor.com).

Note: Remember to include the boiler model number and serial number when ordering parts.

5a

5c

5d

5e

5b

Summary of Contents for WV-DV Series

Page 1: ...WV DV Boilers Series Oil Installation Operation Maintenance Manual...

Page 2: ...inter months as well as shorten the life of the deck materials Refer to Chapter 4 in this manual for specific terminal location requirements Condensate from a side wall vent terminal may also cause pa...

Page 3: ...ILER 4 3 PIPING CONTROLS 5 A BOILER SUPPLY RETURN 5 B SAFETY RELIEF VALVE 5 C TANKLESS WATER HEATER 5 D INDIRECT FIRED WATER HEATER 6 E CONTROLS 6 4 VENTING 7 A VENT SYSTEM INSTALLATION 7 5 BURNER SET...

Page 4: ...instructions and make special notice of potential hazards These categories mean in the judgment of PB Heat LLC USING THIS MANUAL USING THIS MANUAL Indicates a hazardous situation which if not avoided...

Page 5: ...em is installed that reduces the boiler water temperature as the heating load decreases This boiler is not used for any space heating This boiler is part of a modular or multiple boiler system having...

Page 6: ...This boiler is suitable for use on combustible flooring provided the boiler is not set on carpet and a metal drip pan is placed under the appliance 4 See clearance information in Section 1 Preinstall...

Page 7: ...er from condensation Condensation will damage the boiler and will lead to shortened boiler life and maintenance problems 9 If the boiler is to be used in conjunction with a refrigeration system the ch...

Page 8: ...ure 3 4 PIPING CONTROLS IMPORTANT In accordance with Section 325 f 3 of the Energy Policy and Conservation Act water boilers are equipped with a feature that saves energy by reducing the boiler water...

Page 9: ...ly maintained f If the boiler is used to heat potable tap water the boiler will operate year round The effects of hot gases and odors must be taken into consideration during the summer months g See Fi...

Page 10: ...nside 2 Use Z Flex 4 diameter Vent Pipe 3 For air intake use 4 diameter galvanized smoke pipe or 4 diameter flexible corrugated aluminum pipe Maximum equivalent length of galvanized smoke pipe is 40 A...

Page 11: ...circuit board inside burner cover Post purge duration must be a minimum of one minute Adjust dial so arrow is pointing directly to the right toward mounting screw for AL1009 bracket Check post purge...

Page 12: ...y require the addition of a backflow preventer or manual fill only with separation from the city water supply d Consider the minimum temperature of potential exposure in the system when deciding on th...

Page 13: ...65 1 3 3 WV DV 04 115 Hago 85 60 B or Delavan 85 60 W 180 2 5 0 WV DV 04 130 Hago 1 10 60 B or Delavan 1 10 60 W 140 4 5 0 Start up and adjustment recommendations Above Turbulator Pin Air Damper and A...

Page 14: ...National Electrical Code and Local Requirements Single Pole Switches including those of Safety Controls or Protective Devices shall not be wired in a grounded line 6 ELECTRICAL Do not connect power su...

Page 15: ...13 ELECTRICAL Figure 6 2 Hydrolevel 3250 Limit Control Riello Burner...

Page 16: ...es become airborne during service or repair inhalation of these particles may be hazardous to your health Avoid Breathing Fiber Particulates and Dust Suppliers of RCF recommend the following precautio...

Page 17: ...ust be taken not to damage this material during cleaning 4 Remove any scale or soot from the combustion chamber area by vacuum cleaning or any other available means 5 Replace oil burner and flue colle...

Page 18: ...NTENANCE 2 Be certain that the boiler and system are refilled before returning to service Always keep the manual fuel supply valve shut off if the burner is shut down for an extended period of time CA...

Page 19: ...unusual piping and pickup requirements such as intermittent system operation extensive piping systems etc 4 Heating Capacity and Annual Fuel Utilization Efficiency AFUE ratings are based on U S Gover...

Page 20: ...ir Parts Repair parts are available from your local PB Heat LLC distributor or from Parts To Your Door at 1 610 916 5380 www partstoyourdoor com Note Remember to include the boiler model number and se...

Page 21: ...lue Collector Plate Blanket Seal 1 90999 90999 11 Flue Collector Cover Plate 1 50245 50245 12 Rope Seal 2 ft 51209 51209 13 Rear Outlet Cover Plate 1 90563 90563 15 Jacket Assembly 1 90098 90418 Limit...

Page 22: ...20 NOTES...

Page 23: ...ation Operation Maintenance Manual TO THE INSTALLER This manual is the property of the owner and must be affixed near the boiler for future reference TO THE OWNER This boiler should be inspected annua...

Reviews: