17
BOILER DIMENSIONS & RATINGS
8. BOILER DIMENSIONS & RATINGS
Table 8.1: WV-DV Ratings
1.
Boiler Model No. may have the following suffix letters:
a. W–Water, b. P–Packaged, c. C–Circulator, d. T–Tankless Coil
2.
Heating Capacity ratings are based on U.S. Government standard tests, with
13.0% CO².
3.
The water ratings are based on piping pick-up allowance of 1.15. Consult factory
before selecting a boiler for gravity hot water installations and installations
having unusual piping and pick-up requirements, such as intermittent system
operation, extensive piping systems, etc.
4.
Firing rate is based on a fuel oil with a heating value of 140,000 BTU per gallon.
Burner input based on maximum altitude of 2,000 ft. – for other altitudes
consult factory.
(1)
Boiler
Model
Number
(2)
Heating
Capacity
BTU/Hr.
(3)
Net I=B=R Ratings
BTU/Hr.
Water
(4)
I=B=R
Firing
Rate G.P.H.
WV-DV-03-075
92,000
80,000
0.75
WV-DV-03-085
103,000
90,000
0.85
WV-DV-03-110
131,000
114,000
1.10
WV-DV-04-115
141,000
122,000
1.15
WV-DV-04-130
158,000
137,000
1.30
Model
A
B
WV-DV-03
14
¹⁄₈
"
7
¹⁄₁₆
"
WV-DV-04
18
¹⁄₈
"
9
¹⁄₁₆
"
Figure 8.1: WV-DV Boiler Views