PEERLESS PVF Series Installation And Operating Instructions Manual Download Page 3

1.2 Hazard statements

The symbols and hazard statements below may appear in Peerless
installation and operating instructions, safety instructions and
service instructions.

DANGER

Indicates a hazardous situation which, if not avoided, will
result in death or serious personal injury. 

WARNING

Indicates a hazardous situation which, if not avoided,
could result in death or serious personal injury. 

CAUTION

Indicates a hazardous situation which, if not avoided,
could result in minor or moderate personal injury. 

The hazard statements are structured in the following way: 

SIGNAL WORD

Description of the hazard 

 

Consequence of ignoring the warning 

Action to avoid the hazard.

1.3 Notes

The symbols and notes below may appear in Peerless installation
and operating instructions, safety instructions and service
instructions.

FM

Observe these instructions for explosion-proof products. 

A blue or gray circle with a white graphical symbol
indicates that an action must be taken. 

A red or gray circle with a diagonal bar, possibly with a
black graphical symbol, indicates that an action must not
be taken or must be stopped. 

If these instructions are not observed, it may result in
malfunction or damage to the equipment. 

Tips and advice that make the work easier. 

1.4 Target group

These installation and operating instructions are intended for
professional installers and operators of the product.
We recommend that installation be carried out by skilled persons
with technical qualifications required by the specific legislation in
force.

1.5 General safety warnings

WARNING

Personnel qualification

Death or serious personal injury

All operations must be carried out by qualified
personnel.

DANGER

Electric shock

Death or serious personal injury

The electrical installation must be carried out by a
qualified electrician in accordance with local
regulations and the manuals provided with the
electrical accessories.

Before starting any work on the product, make sure
that the power supply has been switched off and that it
cannot be accidentally switched on.

Never do maintenance work on the pump when it is
connected to the power supply.

WARNING

Automatic startup

Death or serious personal injury

Before any inspection, maintenance, service or repair
of the product, make sure that the motor controls are in
the "OFF" position, locked and tagged.

Pumping equipment, especially fire pumps, can start
up at any time. It is imperative to isolate the engine
before doing any maintenance work. Switch off the
main power supply, remove fuses, secure fuel lines,
apply lock-outs where applicable, and affix suitable
isolation warning signs to prevent inadvertent re-
connection.

Isolate the fuel supply to the engine before working on
any part of the fuel supply or control system.

Disconnect the batteries by removal of the negative
terminal connector.

Do not place tools on or near the batteries. This could
result in a short circuit.

Inspect all cables for damage or signs of failure and
replace immediately if damaged.

WARNING

Large openings

Death or serious personal injury

If the site is left unattended before the installation is
complete, all openings must be covered to prevent
entry of children, animals, stones or any other foreign
objects.

Use unbreakable covers that cannot be removed
without tools.

WARNING

Hot surface

Death or serious personal injury

Do not allow skin contact with pump components that
have heated above 108 °F (42 °C).

Wear protective gloves when necessary to touch hot
surfaces. Surfaces may remain hot after unit has been
shut off.

Ensure that drain water from the stuffing box is cool
before contact. The stuffing box on the pump can
become hot in the event of a malfunction or
maladjustment.

WARNING

Hot or freezing surfaces

Death or serious personal injury

Protect persons from contact with hot or freezing
components or auxiliary heating supplies.

If complete protection is not possible, limit access to
maintenance staff only, with clear visual warnings to
those entering the immediate area.

5

English (US)

Summary of Contents for PVF Series

Page 1: ...PVF Vertical inline single stage pumps Installation operation and maintenance manual English Peerless_USLetter_Front_PVF IO fm Page 1 Friday September 13 2019 10 38 PM...

Page 2: ...or wear caused by abrasive materials nor does it cover damage resulting from misuse accident neglect or from improper operation maintenance installation modification or adjustment This warranty does...

Page 3: ...Before starting any work on the product make sure that the power supply has been switched off and that it cannot be accidentally switched on Never do maintenance work on the pump when it is connected...

Page 4: ...Excessive noise Death or serious personal injury If the operating noise level of the product exceeds local code or safe levels over 85 dBA the product must be installed in a controlled access area Pr...

Page 5: ...10 11 12 6 13 14 20 21 22 15 16 17 18 19 6 6 6 6 TM060290 Fig Pump nameplate Pos Description Pos Description 1 Product number 12 Description 2 Nominal flow 13 Description 3 Nominal pressure 14 Serial...

Page 6: ...nd FM approved Approvals B cFMus approved C UL listed approved D NFPA compliant E ULC approved F CCC X Special 1 Cast iron Casing material 2 Ductile iron X Special 7 Silicon bronze ASTM B584 Impeller...

Page 7: ...itable for protection during shipment and during covered storage at a job site for a short period between installation and startup The preservatives applied at the factory have an effective life of tw...

Page 8: ...ommend installing the base plate without the pump Position the foundation and the foundation bolts so that pump inlet and outlet flanges align with the outlet pipes Related information 4 4 2 Foundatio...

Page 9: ...uate headroom must be provided to accommodate the pump to be handled plus the rigging WARNING Overhead load Death or serious personal injury Only lift the entire pump assembly with the lifting lugs pr...

Page 10: ...pockets drill small vent holes through the base surface 5 Level off the grout to be flush with the top of the dam 6 Allow the grout to cure usually 48 to 72 hours before tightening the foundation bol...

Page 11: ...pply before you start any work on the product Make sure that the power supply cannot be switched on accidentally Locate the electrical conduit and boxes so as to avoid obstruction of the pump Check sp...

Page 12: ...otherwise specified by the customer Carefully check the packing allowing a slight leakage for lubrication Do not force the packing into a leak proof position as this will create excessive friction and...

Page 13: ...ates freely 3 Check that the voltage and frequency on the motor nameplate match the current supply 4 Be sure the motor is wired for correct voltage 5 Check that all thermal overload relays are of the...

Page 14: ...e pump WARNING Electric shock Death or serious personal injury Switch off the power supply before you start any work on the product Starting the motor during pump removal could damage pump and may cau...

Page 15: ...st be replaced 1 Measure the outer diameter OD of the impeller wear surface or wear ring 8 and the inner diameter ID of the volute wear ring 7 2 Compute the diametrical clearance ID minus OD and compa...

Page 16: ...depending on the severity of the environment For international destinations this will vary depending on the seaworthiness of the product s export packaging Related information 3 5 Handling and storin...

Page 17: ...attention to the condition of the shaft seals or the packing and O rings Related information 7 1 Storage 7 1 5 Accessories storage Store accessories according to the manufacturer s instructions Relat...

Page 18: ...between sleeve and shaft Check gaskets The suction head is insufficient The suction line is drawing air Tighten the line connections The suction lift is too high or there is insufficient NPSH Reduce...

Page 19: ...r starting Joints are leaking Tighten the joints Tighten the packing Check o ring between sleeve and shaft Replace the gaskets The suction lift is too high or there is insufficient NPSH Reduce the suc...

Page 20: ...rew impeller 83 Stuffing box 27 Ring stuffing box cover 119 O ring 9 Disposing of the product This product or parts of it must be disposed of in an environmentally sound way 1 Use the public or privat...