background image

ISSUED: 12-21-09   SHEET #: 202-9424-1

Universal Flat Wall Mount 

for 10" - 40" Screens

Max UL Load Capacity: 115 lb (52 kg)

©

UL

US

C

This product was designed to be installed on wood stud walls and solid concrete (2000 psi 
density minimum) or cinder block walls. Before installing make sure the supporting surface will 
support the combined load of the equipment and hardware. Screws must be tightly secured. Do 
not overtighten screws or damage can occur or product may fail. Never exceed the Maximum UL 
Load Capacity. This product is intended for indoor use only. Use of this product outdoors could 
lead to product failure or personal injury. For support please call customer care at 1-800-865-2112.

WARNING

Model: PMF2X2

Installation Guide

Summary of Contents for Perfect Mount PMF2X2

Page 1: ...alling make sure the supporting surface will support the combined load of the equipment and hardware Screws must be tightly secured Do not overtighten screws or damage can occur or product may fail Never exceed the Maximum UL Load Capacity This product is intended for indoor use only Use of this product outdoors could lead to product failure or personal injury For support please call customer care...

Page 2: ... 38 ISSUED 12 21 09 SHEET 202 9424 1 Tools Needed for Assembly recommended block wall D 2 E 2 M5 x 6 mm M 4 N 4 M4 x 10 mm F 4 M4 x 20 mm G 4 H 4 M6 x 12 mm J 4 M6 x 20 mm K 4 L 4 P 2 M5 x 12 mm C 1 A 1 B 1 ...

Page 3: ...t A as a template make sure it is level and mark two mounting holes along the 3 A and attach to wall with two wood screws D 7 WOOD STUD A D TOP CUTAWAY VIEW Wood screws must center in stud STUD D A WARNING Do not over tighten screws or damage may occur WARNING TOP CUTAWAY VIEW ...

Page 4: ...4 of 38 ISSUED 12 21 09 SHEET 202 9424 1 Installing to Solid Concrete or Cinder Block 1 Level wall mount A E into holes and secure wall mount A with two wood screws D CINDER BLOCK A D E SOLID CONCRETE ...

Page 5: ...le instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity Q directly to load bearing concrete WARNING 1 2 E A E D concrete A A over anchors E Secure with screws D Tighten screws Drill holes and insert anchors E WARNING CUTAWAY VIEW wall plate drywall wall plate drywall CORRECT INCORRECT concrete concrete ...

Page 6: ...back of screen using four M4 x 10 mm screws F as shown below Note If screw F gets less than three threads of engagement attach adapter plate C to back of screen using four M4 x 20 mm screws G and four spacers H as indicated below Skip to step 4 on page 10 M B N P B C in the screen inserts or if screws bottom out and bracket is still not tightly secured damage may occur to screen or product may fai...

Page 7: ...r to screen or product may fail WARNING 2 2 FOR VESA 200 MOUNTING PATTERN P Q C to back of screen using four M6 x 12 mm screws J as shown below Note If screw J gets less than three threads of engagement attach adapter plate C to back of screen using four M6 x 20 mm screws K If screw K still gets less than three L Skip to step 4 on page 10 C J ...

Page 8: ...mm screws G and four spacers H as indicated below Attaching Hook Bracket to Flat Panel Screen Using VESA 75 and 100 mm mounting patterns 3 1 in the screen inserts or if screws bottom out and bracket is still not tightly secured damage may occur to screen or product may fail WARNING F B For screens with a hole pattern in a pocket spacers H go between hook bracket B and screen H Thread M5 x 12 mm sc...

Page 9: ... VESA 100 MOUNTING PATTERN P Q B to back of screen using four M4 x 10 mm screws F as shown below 3 2 in the screen inserts or if screws bottom out and bracket is still not tightly secured damage may occur to screen or product may fail WARNING B F ...

Page 10: ...nstalling and Removing Flat Panel Screen 4 Hook screen onto wall plate A can handle Use additional man power or mechanical lifting equipment to safely handle placement of the screen SCREEN A force Overtightening can cause damage to mount CAUTION ...

Page 11: ... ISSUED 12 21 09 SHEET 202 9424 1 force Overtightening can cause damage to mount CAUTION Tighten M5 x 12 mm screws P To remove screen from mount loosen screws P and lift screen off of mount DETAIL 1 A P B B A P ...

Page 12: ...12 of 38 ISSUED 12 21 09 SHEET 202 9424 1 ...

Page 13: ...lado en paredes con montantes de madera y en paredes de concreto macizo de una densidad mínima de 2 000 psi o de bloques de hormigón Q la Capacidad Máxima UL de Carga Este producto está diseñado para uso en interiores solamente Utilizar este producto en exteriores podría causar fallas del producto o lesiones a V V P A G G G ADVERTENCIA UL US C Modelo PMF2X2 Guía para la instalación ...

Page 14: ...ecesarias para el ensamblaje localizador de montantes se recomienda uno y de bloque de hormigón de escorias con montantes de madera nivel D 2 E 2 M5 x 6 mm M 4 N 4 M4 x 10 mm F 4 M4 x 20 mm G 4 H 4 M6 x 12 mm J 4 M6 x 20 mm K 4 L 4 P 2 M5 x 12 mm C 1 A 1 B 1 ...

Page 15: ...líneas que pasan por el centro de los montantes de madera de pared A y fíjela a la pared con dos tornillos para madera D en el centro del montante Se reco Q apriete los tornillos en exceso No apriete los tornillos en ADVERTENCIA VISTA SUPERIOR EN CORTE Tornillos para madera en el centro del montante ADVERTENCIA VISTA SUPERIOR EN CORTE Q D A ...

Page 16: ...z GX G Español 1 Instalación en una pared de concreto o de bloques de hormigón de escorias Nivelede el soporte de pared A Inserte dos anclajes E A a la pared con dos tornillos para madera D Q BLOQUE DE HORMIGÓN VP QV P P QP A D E ...

Page 17: ...trar en un vacío o una cavidad V ADVERTENCIA concreto macizo 1 E 2 A E D Coloque la placa A sobre los anclajes E fíjela con los tornillos D Q los tornillos A E CORRECTO INCORRECTO concreto macizo placa de pared placa de pared tabique de yeso cartón tabique de yeso cartón ADVERTENCIA VISTA EN CORTE concreto macizo ...

Page 18: ...adora C usando cuatro tornillos de M5 x 6 mm M y cuatro arandelas N 10 N montaje VESA 200 ó 200 x 100 2 2 1 NOTA VQ PARA LAS CONFIGURACION DE MONTAJE VESA 200 X 100 MM Z C a la parte trasera de la pantalla usando cuatro tornillos de M4 x 10 mm F como se muestra abajo NOTA Si el tornillo F C a la parte trasera de la pantalla usando cuatro tornillos de M4 x 20 mm G y cuatro espaciad ores H como se i...

Page 19: ...y el soporte todavía el producto podría no funcionar bien ADVERTENCIA PARA LAS CONFIGURACION DE MONTAJE VESA 200 Z C a la parte trasera de la pantalla usando cuatro tornillos de M6 x 12 mm J como se muestra abajo NOTA Si los tornillos J C a la parte trasera de la pantalla utilizando cuatro tornillos de M6 x 20 mm K Si los tornillos K L Pase al paso 4 de la página 22 ...

Page 20: ...o cuatro tornillos de M4 x 20 mm G y cuatro espaciad ores de etención H como se indica abajo VESA 75 ó 100 3 1 F B En el caso de las pantallas de agujeros en una cavidad los espaciadores H van entre el placa de montaje B y la pantalla H Enrosque los tornillos de M5 x 12 mm P en el soporte de gancho B hasta que queden a 3 P B B P Si no se les da tres vueltas completas a los tornillos en los inserto...