52
REPAIR PARTS – SERIES 211A
15. REPAIR PARTS – SERIES 211A
1
Intermediate Section
50 psig (345 kPa) Working Pressure
90356
2
Left Hand End Section
50 psig (345 kPa) Working Pressure
90625
3
Right Hand End Section
50 psig (345 kPa) Working Pressure
90059
4
Tapped Intermediate Section
50 psig (345 kPa) Working Pressure
90065
5
Tie Rod
2 Required Per Flueway
90090
6
Flow Port Gasket
2 Required Per Flueway
51670
7
Hi Temp Rope for Sections, 5/8
" (
16mm)
6-1/2 Feet (2 Meter) Required Per Flueway
55723
Base Right End Panel w/Insulation
1 Required Per Boiler
GG2112
Base Left End Panel w/Insulation
1 Required Per Boiler
GG2113
16-7/8" (429 mm) Wide
GG2080
22-1/2" (571 mm) Wide
GG2080-1
9
Base Front Panel Sub-Assembly w/Insulation
28-1/8" (714 mm) Wide
GG2080-2
33-3/4" (857 mm) Wide
GG2080-3
39-3/8
"
(1 m) Wide
GG2080-4
16-7/8" (429 mm) Wide
GG2081
22-1/2" (571 mm) Wide
GG2081-1
10
Base Back Panel Sub-Assembly w/Insulation
28-1/8" (714 mm) Wide
GG2081-2
33-3/4" (857 mm) Wide
GG2081-3
39-3/8" (1 m) Wide
GG2081-4
For 16-7/8" (429 mm) Wide Panel
50848
For 22-1/2" (571 mm) Wide Panel
50849
11
Base Front or Back Panel Insulation
For 28-1/8" (714 mm) Wide Panel
50850
For 33-3/4" (857 mm) Wide Panel
50851
For 39-3/8" (1 m) Wide Panel
50852
12
Base Left/Right End Panel Insulation
1 Required Per Panel
50853
13
Insulation Fastener
Specify Quantity Required
GG2104
14
Burner Support Channel Clip
2 Required Per Boiler
90590
For 16-7/8" (429 mm) Wide Base Panel
90585
For 22-1/2" (571 mm) Wide Base Panel
90586
15
Burner Support Channel
For 28-1/8" (714 mm) Wide Base Panel
90587
For 33-3/4" (857 mm) Wide Base Panel
90588
For 39-3/8
"
(1 m) Wide Base Panel
90589
16
Angle Tie Brace
Specify Quantity Required
90326
Item
Description
Part Selection Information
Stock
No.
Code
Repair parts are available from your installer or by contacting PB Heat, LLC, New Berlinville, PA.
Use the Figures and Tables on Pages 52-55 to assist in ordering parts.
Note: Remember to include boiler model number and serial number when ordering parts.
8
Summary of Contents for 211A-04
Page 1: ...211A Boilers Steam Series Gas Installation Operation Maintenance Manual...
Page 17: ...15 Figure 3 3 Assembling Sections on Base PLACE THE BOILER SECTIONS...
Page 35: ...33 INSTALL CONTROLS AND TRIM Figure 8 2 Pressure Control Piping Fittings Included with Boiler...
Page 40: ...38 WIRE THE BOILER Figure 9 2 Typical Wiring Standard Controls Low Voltage Gas Valves...
Page 41: ...39 WIRE THE BOILER Figure 9 3 Typical Wiring Standard Controls 120 Volt Gas Valves...
Page 51: ...49 BOILER RATINGS DIMENSIONS...
Page 56: ...54 REPAIR PARTS SERIES 211A Figure 15 1 Boiler Assembly...
Page 57: ...55 REPAIR PARTS SERIES 211A Figure 15 2 Base Assembly...
Page 58: ...56 NOTES...