peerless-AV SUA746H Installation And Assembly Manual Download Page 6

6 of 7

ISSUED: 05-01-12 SHEET #: 125-9307-1

•  Tighten screws so display brackets are firmly attached to display. Do not tighten with excessive force. 

Overtightening can cause stress damage to screws, greatly reducing their holding power and possibly causing 

screw heads to become detached.

 

Tighten to 40 in. • lb (4.5 N.M.) maximum torque.

•  If screws don't get three complete turns in the display inserts or if screws bottom out and bracket is still not tightly 

secured, damage may occur to display or product may fail.

WARNING

Installing Adapter Brackets to Display

2

FIGURE 2.1

DISPLAy

ADAPTeR 

PLATe 

keyHOLe SLOT

ADAPTER PLATE MOUNTING DETAIL

 

1/8"

DISPLAy

Use adapter plate detail figure 2.1 to determine  

display hole pattern. 
To prevent scratching the display, set a cloth on a 

flat, level surface that will support the weight of the 

display. Place display face side down. Fasten two M8 

x 10 mm socket pin screws (

J

) or M8 x 15 mm socket 

pin screws (

K

) or M6 x 12 mm socket pin screws (

E

into top mounting holes in back of display as shown in 

figure 2.2 

 

Hook exposed screws into keyhole slots on adapter 

plate on wall arm assembly (A) and secure using two  

M8 x 10 mm socket pin screws (

J

) or M8 x 15 mm 

socket pin screws (

K

) or M6 x 12 mm socket pin 

screws (

E

) into bottom mounting holes  

as shown in figure 2.3.

FIGURE 2.2

FIGURE 2.3

E, J, or K

E, J, or K

   15.75" 

(400 mm)

   15.75" 

(400 mm)

   11.81" 

(300 mm)

   11.81" 

(300 mm)

   7.87" 

(200 mm)

   7.87" 

(200 mm)

Summary of Contents for SUA746H

Page 1: ...a Thin Articulating Mount for Flat Panel Displays Model SUA746H ISSUED 05 01 12 SHEET 125 9307 1 2300 White Oak Circle Aurora Il 60502 800 865 2112 Fax 800 359 6500 www peerless av Max Load Capacity 6...

Page 2: ...truction and fully understands these instructions Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Never exceed the...

Page 3: ...ion Qty Part A wall arm assembly 1 201 P1991 B cable clip 1 046 P1138 C wood screws 2 520 1202 D concrete anchors 2 590 0320 E M6 x 12 mm socket pin screw 4 510 1050 F cable tie 2 046 0136 G 4 mm alle...

Page 4: ...ing wall arm A to wall as shown in figure 1 1 Level then tighten all fasteners Insert two fastener caps H into wall plate mounting holes center of display display mounting plate A C H I Installation t...

Page 5: ...nimum from the side of the block Cinder block must meet ASTM C 90 specifications It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to a...

Page 6: ...ADAPTER PLATE MOUNTING DETAIL 1 8 DISPLAY Use adapter plate detail figure 2 1 to determine display hole pattern To prevent scratching the display set a cloth on a flat level surface that will support...

Page 7: ...d secure cables to cable clip using cable tie J as shown in figure 4 2 Secure cables to cable anchor I using cable tie J as shown below 3 4 Joint screws Roll locking screw B center joint J cables Do n...

Reviews: