peerless-AV KLR62232 Manual Download Page 2

2

2019-06-14    #:150-9227-1

Symbols

ENG

WARNING

ENG

#

Skip to step.

ENG

Do not overtighten screws.

ENG

ENG - This product is designed to be installed on wood stud, solid concrete or cinder block walls. Hardware is 

included for wood stud, solid concrete and cinder block installation. Do not begin to install product until you have 

read and understood the instructions and warnings contained in this user guide. Before installing make sure 

the supporting surface will support the combined load of the equipment and hardware. Screws must be tightly 

secured. Do not overtighten screws or damage can occur and product may fail. Never exceed the Maximum 

Load Capacity. Always use an assistant or mechanical lifting equipment to safely lift and position equipment. This 

product is intended for indoor use only. Use of this product outdoors could lead to product failure or personal 

injury. Be careful not to pinch fingers when operating the mount. To reduce the risk of electric shock or fire, do not 

expose product to water or moisture. Be sure power cord is routed so that it will not be tripped on, stepped on, 

or pinched by heavy items. Avoid overloading electrical outlets or extension cords. Always disconnect the power 

cord from the power outlet when installing, servicing, or not using the product for an extended period of time. Do 

not block ventilation slots or fan exhaust on product. Blocking airflow could damage product. Arrange product to 

allow air to flow freely around product. Keep product away from direct sunlight or any source of heat. For support 

please call 800-4-SIGNAGE.

 WARNING

Summary of Contents for KLR62232

Page 1: ...1 2019 06 14 150 9227 1 ENG KLR62232 KLR64255...

Page 2: ...al lifting equipment to safely lift and position equipment This product is intended for indoor use only Use of this product outdoors could lead to product failure or personal injury Be careful not to...

Page 3: ...14 150 9227 1 Tools Needed for Assembly ENG 1 2 ENG To properly tighten screws Tighten until screw head makes contact then tighten another 1 2 turn Do not overtighten screws 4 1 2 3 5 32 4mm 5 16 8mm...

Page 4: ...2 1544 152 1545 B wall mount 1 ST635 ST640 C 14 x 2 1 2 wood screw 4 5S1 015 C03 5S1 015 C03 D 8mm concete anchor 4 590 0320 590 0320 E power strip 1 600 0370 600 0370 F locking bracket 1 152 T1502 15...

Page 5: ...5 2019 06 14 150 9227 1 D 4 8mm concrete anchor C 4 14 x 2 1 2 wood screw H 3 M5 x 20mm 1 B Follow and complete instructions for included wall mount ENG...

Page 6: ...6 2019 06 14 150 9227 1 2 B A Hold enclosure over display in desired location and make sure that it is level Mark the top location of the enclosure ENG 3 Remove display ENG Loosen ENG 4mm...

Page 7: ...a wood stud wall covered with gypsum board drywall verify that the wood studs are a minimum of 2 x 4 nominal size Do not install over gypsum board thicker than 5 8 WARNING Wood stud wall ENG Concrete...

Page 8: ...8 2019 06 14 150 9227 1 4a 2 G B G B Mark mounting holes on stud center lines Mounting holes should be positioned 1 8 under the horizontal cover line ENG cover line ENG cover line ENG...

Page 9: ...4a 3 5 32 4mm C 2 G B Mounting hole must center on stud ENG 2 5 64mm 5 32 4mm Drill mounting holes into supporting surface 2 5 64mm minimum depth required ENG Level wallplate Install using wood screws...

Page 10: ...m the side of the block It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a vo...

Page 11: ...11 2019 06 14 150 9227 1 4b 4 3 8 10mm 1b 3 4b 3 D 2 C 2 G Insert anchor flush to concrete ENG D Level wallplate Install using wood screws provided ENG Maximum 80 in lb 9 N M ENG...

Page 12: ...12 2019 06 14 150 9227 1 5 A B G G 6 Hang enclosure onto hook on bracket ENG Mark the bottom location of the enclosure ENG G A Enclosure must fully seat onto bracket ENG...

Page 13: ...ts on a wood stud wall covered with gypsum board drywall verify that the wood studs are a minimum of 2 x 4 nominal size Do not install over gypsum board thicker than 5 8 WARNING Wood stud wall ENG Con...

Page 14: ...8 10mm 7a 2 5 32 4mm Mounting hole must center on stud ENG 2 5 64mm 5 32 4mm Drill mounting holes into supporting surface 2 5 64mm minimum depth required ENG Level wallplate Install using wood screws...

Page 15: ...15 2019 06 14 150 9227 1 This page intentionally left blank ENG...

Page 16: ...solid part of the block generally 1 25 mm minimum from the side of the block It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoi...

Page 17: ...17 2019 06 14 150 9227 1 C 2 7b 4 3 8 10mm 1b 3 7b 3 D 2 Insert anchor flush to concrete ENG D Level wallplate Install using wood screws provided ENG Maximum 80 in lb 9 N M ENG F...

Page 18: ...18 2019 06 14 150 9227 1 8 10 9 Tighten Apretar Serrer Anziehen Aandraaien Stringere Ut hn te Utiahnite Apertar S kmak ENG ESP FRN DEU NEL ITL E SLK POR T R 4mm...

Page 19: ...19 2019 06 14 150 9227 1 11 A 12 Do not overtighten screws ENG 4mm H 3 G...

Page 20: ...s to conform with this warranty Any implied warranty of merchantability or fitness for a particular purpose shall be limited to the period of the express warranty set forth below In no event shall Pee...