peerless-AV HF642-003 Installation And Assembly Manual Download Page 5

5 of 7

ISSUED: 04-10-12   SHEET #: 125-9295-2  04-26-12

SOLID CONCReTe

CINDeR BLOCK

Installation to Solid Concrete or Cinder Block

•  When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35mm) of actual 

concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount 

in a solid part of the block, generally 1" (25mm) minimum from the side of the block. Cinder block must meet ASTM 

C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a 

hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

•  Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•  Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware 

and components.

WARNING

1

CUT

AW

AY

 VI

eW

INCoRReCT

CoRReCT

wall 

plate

wall 

plate

plaster/

dry wall

plaster/

dry wall

concrete

concrete

1

3

2

 K

Drill holes and insert anchors (

K

).

Place plate (

A

) over anchors (

K

) and secure with screws (

I

).

Tighten all fasteners.

  A

 K

   I

concrete 

surface

•  Tighten screws so that wall plate is firmly attached, 

but do not overtighten. Overtightening can damage 

screws, greatly reducing their holding power.

•  Never tighten in excess of 80 in. • lb (9 N.M.).
•  Always attach concrete expansion anchors directly

 

to load-bearing concrete.

•  Never attach concrete expansion anchors to 

concrete covered with plaster, drywall, or other 

finishing material. If mounting to concrete surfaces 

covered with a finishing surface is unavoidable, 

the finishing surface must be counterbored as 

shown below. Be sure concrete anchors do not 

pull away from concrete when tightening screws. If 

plaster/drywall is thicker than 5/8" (16mm), custom 

fasteners must be supplied by installer.

WARNING

Make sure that wall plate (

A

) is level, use it as a 

template to mark four mounting holes. Drill four 5/16" 

(8mm) dia. holes to a minimum depth of 2.5" (64mm). 

Insert anchors (

K

) in holes flush with wall as shown 

(right). Place wall plate over anchors and secure with 

#14 x 2.5" screws (

I

). Level, then tighten all fasteners.

A

I

K

NoTe:

 DIAMOND INDICATeS 

TOP OF WALL PLATe 

Summary of Contents for HF642-003

Page 1: ...6 2300 White Oak Circle Aurora Il 60502 800 865 2112 Fax 800 359 6500 www peerless av com Installation and Assembly Ultra Thin Flat Panel Wall Mount for VESA 400 x 400 Mounting Hole Patterns Model HF6...

Page 2: ...d by someone of good mechanical aptitude has experience with basic building construction and fully understands these instructions Make sure that the supporting surface will safely support the combined...

Page 3: ...mm allen wrench 1 560 1129 F M8 x 10 mm socket pin screw 4 520 1706 G M8 x 15 mm socket pin screw 4 520 1068 H 4 590 2233 I 4 5S1 015 C03 J 4 520 9521 K concrete anchor 4 590 0320 L toggler 4 560 9708...

Page 4: ...e 1 2 Skip to step 2 Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that wall...

Page 5: ...crete concrete 1 3 2 K Drill holes and insert anchors K Place plate A over anchors K and secure with screws I Tighten all fasteners A K I concrete surface Tighten screws so that wall plate is firmly a...

Page 6: ...gglers are anchored into the center of the studs as shown in figure 1 The use of an edge to edge stud finder is highly recommended WARNING Installation to Metal Stud Wall 1 Rotate toggler L clockwise...

Page 7: ...3 1 Detail 2 Secure right and left hook brackets B and C to wall plate A with two M5 x 10 mm socket pin Type F screws M using 4 mm allen wrench E as shown in Detail 3 3 FIGURE 3 1 Attaching Hook Brac...

Reviews: