Pecron S1500 User Manual Download Page 9

Q1: What kind of battery is used in S1500? How long it can last?

  A: 

S1500 utilizes high quality UL certified automotive battery cell, it can retain 80% efficiency at 1000 complete 

         charge cycles.

Q2: What devices can S1500 power?

  A:

  

The AC output ports can power appliances which use less than 1500 watts of electricity. However, inductive types of 

          loads such as freezer, fridge, compressor, motor require a much higher power to start (approx. 3-7 times lager than 
          its rated power). The DC output ports can supply a maximum DC power of 120W(12V@10A).

Q3: Can the S1500 be used as UPS?

  A:

  The UPS function is not supported.

Q4: How to calculate the S1500 running time?

  A: Running Time=Total Capacity(1461.6Wh) * 0.85 (Depth of Discharge)/Loading Power(Watts)

Q5: Can I use the S1500 indoors and charge the S1500 indoors?

  A: Yes, the S1500  is safe to use indoors.

Q6: Does S1500 have built-in charge controller?

  A: 

 

Yes, there is a built-in PWM charge controllers, which supports 29.4-40V, 20A maximum PV input;

Q7: What kind of maintenance does S1500 require?

  A: Charging S1500 in time when the battery running low; And please charge it at least once for every six months 

         even if it is not being used.

Q8: How to store the S1500?

  A: Do not store, charge or use S1500 near heat sources, or in an area exposed to flammable or corrosive gas;  

         Do not immerse in water. Keep away from liquids and store it in a cool and dry place.

FAQS

Please read the user manual thoroughly before using this product, and keep this manual in a safe place for future reference. 

Failure to follow the instructions for proper set up, use, and care for the device can increase the risk of serious personal 

injury, death, or property damage. Once you use this device, you are deemed to have understood, recognized and accepted 
all terms and contents of this document. The user shall be responsible for his own actions and all consequences arising from 
failure to use the device in accordance with the “User Manual”, or as authorized in Pecron's current product literature.

[email protected]

DISCLAIMER

Summary of Contents for S1500

Page 1: ...Please read the user manual thoroughly before using support pecron com S1500 USER MANUAL DC12V10A OUT DC29 4V15A IN ...

Page 2: ...ron com FUNCTION INTRODUCTION LCD Display USB A Ports Air Vent DC 12V 10A Output DC 29 4V15A Input AC 110V Output Air Vent Ground receptacle Power Switch DC 12V USB Switch AC 110V Switch DC12V10A OUT DC29 4V15A IN ...

Page 3: ...nd 27lb Around 12 5kg 1461 6Wh 25 2V58Ah Protections Over Voltage Overheat Overload Short Circuit Self Recovery Temperature 0 45 32 F 113 F Charging 20 45 4 F 113 F Discharging AC Out 3 Pure sine wave 110V Rated 1500W USB A 4 5V 9V 12V Max 18W 1 12V 10A 16MF Aviation DC Charging Time 3 4 H AC Charger AC Charging 29 4V Max 15A Solar Charging 36V 20A 29 4V 5A Car Charging 12 5kg ...

Page 4: ... your device is more than 1500W The AC overload alarm will flash The power supply will stop working Temperature Alarm Icon S1500 can power your devices at temperatures ranging from 20 45 If your working temperature is more than 45 the temperature alarm will flash the unit may stop working Charge Indicator Discharge Indicator Net Input Output Wattage AC Output Wattage W Voltage V AC Overload Alarm ...

Page 5: ...ther conditions The included external MPPT charge controller supports 32 95V PV input that allows you to charge the S1500 30 faster via solar panels 200W 1 9 10 Hours Recommended 400W 2 4 5 Hours Recommended 600W 3 3 3 5 Hours Recommended 4 In 1 DC Output Adapter 1 Pecron S1500 1 AC Charger 1 MPPT Charger 9029 1 Car Charger DC1229 1 MPPT Charger 9029 1 Wall Charger ...

Page 6: ...aximum VOC open circuit voltage of solar panel must be less than 45V 2 MPPT charger INPUT DC 32V 95V 500W maximum OUTPUT DC 29 4V15A 3 If you have any questions Please feel free to contact us support pecron com DC12V10A OUT DC29 4V15A IN DC29 4V15A IN PV 29 4 40V 20A Maximum Input DC29 4V15A IN ...

Page 7: ...ecron 200W 36V 1 200W to charge the S1500 36V is the operating voltage of the solar panels Using the pecron 200W 36V 2 400W to charge the S1500 pecron 200W 2 36V is the operating voltage of the solar panels DC 29 4V15A IN DC 29 4V15A IN MPPT Charger 9029 1 MPPT Charger 9029 1 36V 36V ...

Page 8: ...om 32V 95V Voc connecting solar panels over 95V will damage the controller Using the pecron 200W 36V 3 600W to charge the S1500 Y Branch MC4 Charging Cable 1 Y Branch MC4 Charging Cable 1 pecron 200W 3 36V is the operating voltage of the solar panels DC 29 4V15A IN MPPT Charger 9029 1 DC 29 4V15A IN NOTE This parallel charging cable sold separately 36V 36V 36V ...

Page 9: ...harge controllers which supports 29 4 40V 20A maximum PV input Q7 What kind of maintenance does S1500 require A Charging S1500 in time when the battery running low And please charge it at least once for every six months even if it is not being used Q8 How to store the S1500 A Do not store charge or use S1500 near heat sources or in an area exposed to flammable or corrosive gas Do not immerse in wa...

Page 10: ...nt vibration Please turn off the device immediately and stop using it in the event of major exterior impact Please fasten the unit firmly during transportation to avoid vibration and impact 11 In the event of immersing the device into the water accidently please place the unit in a safe open area and keep away from the unit until it is completely dry The dried unit should not be reused and should ...

Page 11: ... recycling and disposal 2 If the battery cannot be completely discharged due to the failure of the product itself please do not dispose of the battery directly in the battery recycling box and contact a professional battery recycling company for further disposal 3 The battery will not be able to start after being over discharged please dispose of it according to the principle of disposal Pecron s ...

Page 12: ...POWER IT POSSIBLE www pecron com support pecron com ...

Reviews: