Pecan Engineering Nectre Inbuilt LE Installation Instructions Download Page 2

 

 

 

 

 

 

 

 

 

Most building regulatory Authorities in Australia require any 
wood heater installation to comply with Installation Standard 
AS/NZS 2918:2001. Different states and councils may have 
varying regulations. Check local building regulations before 
installing the appliance. 

All Nectre wood heaters have been tested to ensure that they 
will meet the appropriate safety Standard requirements if the 
instructions in this manual are followed. As the safety and 
emissions performance can be affected by altering the 
appliance, no modifications are allowed without written 
permission from the manufacturer. 

WE RECOMMEND THAT THE INSTALLATION OF YOUR 
NECTRE WOOD HEATER BE CARRIED OUT BY A QUALIFIED 
INSTALLER. 

WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE 
INSTALLED IN ACCORDANCE WITH AS/NZS 2918:2001 AND 
THE APPROPRIATE REQUIREMENTS OF THE RELEVANT 
BUILDING CODE OR CODES. 

WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH 
THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS 
OF AS/NZS 4012 & AS/NZS 4013 WHERE REQUIRED BY THE 
REGUALTORY AUTHORITY, I.E. THE APPLIANCE SHALL BE 
IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING 
‘TESTED TO AS/NZS 4012 & AS/NZS 4013’. 

ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT 
BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY 
IS CONSIDERED TO BE IN BREACH OF THE APPROVAL 
GRANTED FOR COMPLIANCE WITH AS/NZS 4012 & AS/NZS 
4013. 

CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM 
COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING 
THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY 
RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION 
IS CONSIDERED, THE MANUFACTURER SHOULD BE 
CONSULTED IN THE FIRST INSTANCE. 

CAUTION: CRACKED AND BROKEN COMPONENTS, EG. GLASS 
PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION 
UNSAFE. 

 

 

The Nectre Inbuilt LE is designed to be installed in a 
concrete, brick or stone fireplace which is attached to a 
chimney and has a non-combustible floor protector. 

1)

 

Check and clean the chimney and fireplace.  

2)

 

Prepare the opening so that the heater will seal against 

the sides of the fireplace. If the opening is too large it 

can be reduced by fitting a sheet of heat tolerant 

material such as compressed cement sheet, or bricks, or 

with optional steel facias available from Nectre. 

3)

 

The flue spigot in the heater is 45°. For a vertical flue, a 

150mm 45° stainless steel flue bend needs to be fitted. 

4)

 

Wrap the supplied fibreglass insulation around the rear 

of heater. To avoid heat losses through the sides of the 

heater into the fireplace cavity, it is recommended to fit 

fibreglass or rock-wool insulation to the external sides 

of the heater. 

5)

 

Install flue lengths up the chimney to atmosphere. 

6)

 

Insert the heater, and by gaining access through the 

removed top panel, fit the flue and 45° elbow together. 

7)

 

Refit the top panel into place. 

The flue kit must be installed according to the 
manufacturer’s instructions. 

 

 

THE INSTALLATION INSTRUCTIONS IN THIS 
MANUAL APPLY TO THE NECTRE INBUILT LE. 

IT HAS BEEN TESTED FOR EMISSIONS AND EFFICIENCY 
AND COMPLIES ACCORDING TO AS/NZS 4012:1999 & 
AS/NZS 4013:1999. 

1. IMPORTANT INFORMATION 

2. INSTALLING THE HEATER 