- 11 -
4. Energize the converter. See
Section 4.4
entitled
Automatic Average Current Density Control
with Current Limit Adjustment Procedure
for details.
5. Adjust the "output adjust" knob to the desired current level. The converter will hold the desired
current level constant for varying load conditions.
NOTE
: The converter will hold the desired current level for an operating range
from 10% to 100% of the converter's full rated output voltage.
4.6
Conversion to Current Mode of Control
The conversion from voltage mode to current mode of control is easily accomplished.
1. Open the front panel of the converter and locate the terminal strip mounted on the control panel.
2. Locate the control wires, No. 7 and No. 8 on the terminal strip. See
Figure 2
.
3. Remove wire No. 7 (blue) from the terminal and wire No. 8 (blue) from its terminal.
4. Plug wire No. 7 (blue) on wire No. 8 terminal and plug wire No. 8 (blue) on wire No. 7 terminal.
See
Figure 6
.
5. For conversion back to voltage mode of control, reverse steps 3 and 4. See
Figure 7
.
Figure 6
Wiring Connection for Current Mode of Operation
Figure 7
Wiring Connection for Voltage Mode of Operation