Peavey TKO 115 Supplementary Manual Download Page 2

2

Intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure
that may be of sufficient magnitude to constitute a risk of electric shock to persons.

Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the 
literature accompanying the product.

CAUTION: Risk of electrical shock – DO NOT OPEN!
CAUTION: To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to 
qualified service personnel.

WARNING: To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this 
appliance, read the operating guide for further warnings.

Este símbolo tiene el propósito de alertar al usuario de la presencia de "(voltaje) peligroso" que no tiene 
aislamiento dentro de la caja del producto que puede tener una magnitud suficiente como para constituir riesgo de 
corrientazo.

Este símbolo tiene el propósito de alertar al usario de la presencia de instruccones importantes sobre la operación 
y mantenimiento en la literatura que viene con el producto.

PRECAUCION: Riesgo de corrientazo – No abra.
PRECAUCION: Para disminuír el riesgo de corrientazo, no abra la cubierta. No hay piezas adentro que el usario pueda 
reparar. Deje todo mantenimiento a los técnicos calificados.

ADVERTENCIA:  Para evitar corrientazos o peligro de incendio, no deje expuesto a la lluvia o humedad este aparato 
Antes de usar este aparato, lea más advertencias en la guía de operación.

Ce symbole est utilisé pur indiquer à l'utilisateur la présence à l'intérieur de ce produit de tension non-isolée 
dangereuse pouvant être d'intensité suffisante pour constituer un risque de choc électrique.

Ce symbole est utilisé pour indiquer à l'utilisateur qu'il ou qu'elle trouvera d'importantes instructions sur 
l'utilisation et l'entretien (service) de l'appareil dans la littérature accompagnant le produit.

ATTENTION: Risques de choc électrique – NE PAS OUVRIR!
ATTENTION:  Afin de réduire le risque de choc électrique, ne pas enlever le couvercle. Il ne se trouve à l'intérieur 
aucune pièce pouvant être réparée par l'utilisateur. Confier l'entretien à un personnel qualifié.

AVERTISSEMENT: Afin de prévenir les risques de décharge électrique ou de feu, n'exposez pas cet appareil à la pluie 
ou à l'humidité. Avant d'utiliser cet appareil, lisez les avertissements supplémentaires situés dans le guide.

Dieses Symbol soll den Anwender vor unisolierten gefährlichen Spannungen innerhalb des Gehäuses warnen, die 
von Ausreichender Stärke sind, um einen elektrischen Schlag verursachen zu können.

Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam machen, die 
Handhabung und Wartung des Produkts betreffen.

VORSICHT: Risiko – Elektrischer Schlag! Nicht öffnen!
VORSICHT: Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es befinden sich 
keine Teile darin, die vom Anwender repariert werden könnten. Reparaturen nur von qualifiziertem Fachpersonal 
durchführen lassen.

ACHTUNG:  Um einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses Gerät nicht dem Regen oder 
Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen.

Summary of Contents for TKO 115

Page 1: ...1 Cover for TKO 115 ...

Page 2: ...ymbole est utilisé pur indiquer à l utilisateur la présence à l intérieur de ce produit de tension non isolée dangereuse pouvant être d intensité suffisante pour constituer un risque de choc électrique Ce symbole est utilisé pour indiquer à l utilisateur qu il ou qu elle trouvera d importantes instructions sur l utilisation et l entretien service de l appareil dans la littérature accompagnant le p...

Page 3: ...ow frequencies increases the possibility of speaker damage and sacrifices valuable headroom HIGH EQ CONTROL 7 An active tone control shelving type 15 dB that varies the high frequency boost or cut GRAPHIC SELECT 8 The in position of this switch routes the instrument signal through the 7 band equalizer The out position removes the graphic equalizer from the signal path GRAPHIC EQUALIZER 9 This seve...

Page 4: ...reo headset POWER LED 15 Illuminates when AC power is being supplied to the amp POWER SWITCH 16 Depress to On position to turn on LINE MAINS CORD RETAINERS 17 Allow storage of mains cable for travel GROUND SWITCH 18 Three position rocker type switch which in most applications should be operated in its center or zero position There may be some situations when audible hum and or noise will come from...

Page 5: ... IN IN OUT OUT IN OUT Tone settings given are general and will vary according to type of guitar type and gauges of strings type of pickup and even type of pick Personal taste playing style and type of music greatly contribute to desired tonality ...

Page 6: ...V RMS Minimum Input Level 34 dBV 20 mV RMS Maximum Input Level 16 dBV 6 V RMS Effects Patch Send High Pass Output Load Impedance 10 K ohms or greater Nominal Output Level 12 dBV 0 25 V RMS Maximum Output Level 8 dBV 2 5 V RMS Effects Patch Return Impedance High Z 22 K ohms Designed Input Level 12 dBV 0 25 V RMS Remixes with Main Full Range Signal designed for Low Level chorus or flange Preamp Outp...

Page 7: ...cuencias agudas 7 Un control de tono activo tipo repisa 15 dB que varía el impulso o la reducción de las frecuencias agudas GRAPHIC SELECT Selección del ecualizador gráfico 8 La posición In hacia dentro de este interruptor hace pasar la señal del instrumento por el ecualizador de 7 bandas La posición Out hacia fuera aparta al ecualizador gráfico del camino de la señal GRAPHIC EQUALIZER Ecualizador...

Page 8: ...corriente 16 Empuje éste interruptor para encender el aparato LINE MAINS CORD RETAINERS Guardacable para cables principales 17 Permite almacenar los cables principales para traslado GROUND SWITCH Interruptor de tierra 18 Un interruptor tipo balancín de tres posiciones que en la mayoría de las aplicaciones debe ser operado en su posición del centro o cero 0 Puede haber situaciones cuando un zumbido...

Page 9: ...to the nearest other PEAVEY AUTHORIZED DEALER or AUTHORIZED PEAVEY SERVICE CENTER which can provide such service OR b Ship the defective item prepaid to PEAVEY ELECTRONICS CORPORATION International Service Center 326 Hwy 11 80 East MERIDIAN MS 39301 including therewith a complete detailed description of the problem together with a legible copy of the original PROOF OF PURCHASE and a complete retur...

Page 10: ...C A I S F R A N C A I S D E U T S C H E N G L I S H E N G L I S H HIGH GAIN INPUT 1 Used for most electric basses It is 6 dB louder than the Low Gain Input LOW GAIN INPUT 2 Provided for instruments that have extremely high outputs which can result in overdriving distorting the High Gain Input If both inputs are used simultaneously the output levels are the same both are High Gain PRE GAIN 3 Contro...

Page 11: ...ther PEAVEY AUTHORIZED DEALER or AUTHORIZED PEAVEY SERVICE CENTER which can provide such service OR b Ship the defective item prepaid to PEAVEY ELECTRONICS CORPORATION International Service Center 326 Hwy 11 80 East MERIDIAN MS 39301 including therewith a complete detailed description of the problem together with a legible copy of the original PROOF OF PURCHASE and a complete return address Upon P...

Page 12: ...C A I S F R A N C A I S D E U T S C H E N G L I S H E N G L I S H HIGH GAIN INPUT 1 Used for most electric basses It is 6 dB louder than the Low Gain Input LOW GAIN INPUT 2 Provided for instruments that have extremely high outputs which can result in overdriving distorting the High Gain Input If both inputs are used simultaneously the output levels are the same both are High Gain PRE GAIN 3 Contro...

Page 13: ...priate Peavey catalog publication Bass Guitars Guitars Bass Amplification Guitar Amplification Sound Reinforcement Enclosures Microphones Keyboards DJ Lighting Mixers Powered Non Powered Accessories Cables Effects Processors Axcess Wear The Peavey Beat Monitor Magazine Key Issues Low Down PM Magazine ...

Page 14: ...arranties and the other terms and conditions expressed herein have been complied with Peavey will provide the necessary warranty service to repair or replace the product and will return it FREIGHT COLLECT to you the purchaser Peavey s liability to the purchaser for damages from any cause whatsoever and regardless of the form of action including negligence is limited to the actual damages up to the...

Page 15: ...old cleaner if necessary Disconnect unit from power supply before cleaning 14 Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other openings 15 This unit should be checked by a qualified service technician if a The power supply cord or plug has been damaged b Anything has fallen or been spilled into the unit c The unit...

Page 16: ...16 Features and specifications subject to change without notice Peavey Electronics Corporation 711 A Street Meridian MS 39301 U S A 601 483 5365 Fax 486 1278 1995 80302261 Printed in U S A 3 95 ...

Reviews: