Peavey Sanctuary Series SSE UB2T Specifications Download Page 11

Notes:

SPECIFICATIONS       

 

SSE

 UB2T 

11

Summary of Contents for Sanctuary Series SSE UB2T

Page 1: ...al coverage array providing mid high frequency coverage of an entire small room or under a balcony or other barrier spot delay coverage Constructed of premium plywood for strength rigidity and light weight the SSE UB2T has a perforated metal grille covered with cloth for a subtle appearance Built in hanging points provide stability and flexibility in coverage adjustment This mid high frequency qua...

Page 2: ...and system power rating and will result in failure of the speaker system Enclosure Materials Finish Premium plywood finished in black or white paint Mounting Provisions Flying point for suspension bracket included Overall Dimensions H x W x D 3 23 x 13 78 x 6 12 82 mm x 350 mm x 155 mm Net Weight 5 lbs 2 3 kg Frequency Response This measurement is useful in determining how accurately a given unit ...

Page 3: ...and a peak power input of at least 200 watts with a minimum amplifier headroom of 3 dB for the 8 ohm input The transformer input maximum continuous power handling shall be 30W with a maximum peak power of 60W for either a 100V or 70V input line The nominal radiation geometry shall be 180 degrees in the horizontal plane and 90 degrees in the vertical plane The overall outside dimensions shall be 3 ...

Page 4: ...200 500 1k 2k 5k 10k 20k Frequency Hz 40 50 60 70 80 90 100 110 dB SPL re 20 Pa Harmonic Distortion 1 Rated Power Figure 5 3rd Harmonic 2nd Harmonic 20 50 100 200 500 1k 2k 5k 10k 20k Frequency Hz 50 60 70 80 90 100 110 120 dB SPL re 20 Pa Harmonic Distortion 10 Rated Power Figure 6 3rd Harmonic 2nd Harmonic 4 ...

Page 5: ... 0 o 30 o 60 o 90 o 30 o 60 o 90 o 1 6 kHz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 0 o 30 o 60 o 90 o 30 o 60 o 90 o 2 kHz 2 5 kHz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 1 kHz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 250 Hz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 400 Hz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 630 Hz Vertical Polar Plots 1 3 octave averaged plotted on ISO 1 3 octave centers from 200 Hz 16 kHz SPECIFICATIONS SSE...

Page 6: ... 60 o 90 o 30 o 60 o 90 o 0 o 30 o 60 o 90 o 30 o 60 o 90 o 0 o 30 o 60 o 90 o 30 o 60 o 90 o 0 o 30 o 60 o 90 o 30 o 60 o 90 o 0 o 30 o 60 o 90 o 30 o 60 o 90 o 10 kHz 6 3 kHz 4 kHz 16 kHz 12 5 kHz 8 kHz 5 kHz 3 15 kHz Vertical Polar Plots 1 3 octave averaged plotted on ISO 1 3 octave centers from 200 Hz 16 kHz ...

Page 7: ...o 90 o 1 6 kHz 800 Hz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 90 o 60 o 30 o 0 o 30 o 60 o 90 o 2 kHz 2 5 kHz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 1 kHz 500 Hz 315 Hz 200 Hz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 400 Hz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 630 Hz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 250 Hz Horizontal Polar Plots 1 3 octave averaged plotted on ISO 1 3 octave centers from 200 Hz 16 kHz SPECIFICATIONS S...

Page 8: ...0 o 30 o 60 o 90 o 90 o 60 o 30 o 0 o 30 o 60 o 90 o 90 o 60 o 30 o 0 o 30 o 60 o 90 o 90 o 60 o 30 o 0 o 30 o 60 o 90 o 90 o 60 o 30 o 0 o 30 o 60 o 90 o 90 o 60 o 30 o 0 o 30 o 60 o 90 o 90 o 60 o 30 o 0 o 30 o 60 o 90 o 90 o 60 o 30 o 0 o 30 o 60 o 90 o 10 kHz 6 3 kHz 4 kHz 16 kHz 12 5 kHz 8 kHz 5 kHz 3 15 kHz ...

Page 9: ...nto the ceiling wall in the orientation selected being sure to install it using the appropriate fastener nominally a 1 4 x 3 lag bolt into an inner wall or ceiling stud Never drive a lag bolt into just drywall or just paneling as this will not hold the cabinet safely Consult a certified structural engineer for all mounting details The wall fastener will go through the appropriate bracket hole with...

Page 10: ...10 Input Plate ...

Page 11: ...Notes SPECIFICATIONS SSE UB2T 11 ...

Page 12: ...oration 5022 Hartley Peavey Drive Meridian MS 39305 601 483 5365 FAX 601 486 1278 EX000040 2005 by Logo referenced in Directive 2002 96 EC Annex IV OJ L 37 38 13 02 03 and defined in EN 50419 2005 The bar is the symbol for marking of new waste and is applied only to equipment manufactured after 13 August 2005 ...